/ /Wood floor&wall framing by others <br /> � Connection of floor members to sill plate <br /> to be per Code by others <br /> 2x6 minimum sill plate w/1/2"diameter <br /> anchor bolts wl 7"minimum embed&2" <br /> wide x�l8"thick square or round <br /> countersunk washers or alternative <br /> anchor(Anchor bolt clearance between <br /> edge of both wall and sill plate is to be <br /> �2.5")(see table below for spacing) <br /> Grade to be at least 6"below top of wall <br /> Exterior top of wall may have a brick <br /> ledge provided the stem wall formed is <br /> at least 6"thick&no more than 16"high <br /> Continuous#4 horizontal bars,provide <br /> � at least(2)@ 8'-0"clear,(3)@ 9'-0" <br /> rn <br /> 'a� clear,&(4)@'10'-0"clear,At <br /> = contractor's option: The lowest wall <br /> � horizontal bar may be omitted if(2)#4 <br /> U continuous horizontal bars are placed in <br /> the footing <br /> Cast-in-place concrete foundation wall <br /> wl#6 or equivalent vertical bars placed <br /> �.5"from inside face,see table below for <br /> spacing <br /> #4 x 2'-0"long dowels @ 72"o.c.max wl <br /> 5"minimum embed <br /> Unreinforced concrete strip footing per <br /> Code by others,elevation below slab <br /> may vary as required <br /> BASEMENT WALL DETAIL <br /> Clear Hei ht and Soil T Table Notes: <br /> Wall 8'or Less 9' 10' (1)= Unreinforced if concrete is 4000 psi or if <br /> Thlckness Sand SC Clay Sand SC Clay Sand SC Clay clear height is 4"less <br /> Vertical Rebar 3 acin (2)= Unreinforced if concrete is 5000 psi or if <br /> $" NA NA 36"(1 NA 36"(2 36" 36"(1 36" 24" clear height is 4"less <br /> 10" NA NA NA NA NA 36"(1 NA 36"(1 36" Allowed alternate a�chors are: <br /> 12" NA NA NA NA NA NA NA NA NA MAB/ST,MASA/FA3,FWAZ,or 112" <br /> Sill Anchor 3 cln diameter expansion bolts wl 6"min embed <br /> Bolts 72" 72" 48" 72" 48" 36" 60" 36" 24" (install in accordance with the <br /> Alternate 48" 24" is" 36" i8" 12" 24" 12" S" manufacturer's recommendations) <br /> Oswell EnglneeNng and Consulting,L.L.C. 1901 E Hennepin Ave.#201 ,'�;� � -'*�'"=f:� <br /> Project Name: 2017 Standardized Concrete Foundation Drawings Mlnneapolls,MN bb413 , �� <br /> ' , <br /> Description: Full Height Wall Detail(NOT TO SCALE) Phone:612-720-4839 ;�; '•� <br /> Project# 16.100 Fax:612-886-2988 � '' <br /> :x <br /> Client Name: Abfalter Brothers Concrete LLC WWW.OSWeIIeC.Com �,�. <br /> Client Address: '15546 Cleveland Street,Elk River,MN 55330 Page S6 of S6 w�a,• ,. - �► ��.. <br /> 1/1/2017 <br />