Laserfiche WebLink
' '- 'tg � ► <br /> • . � <br /> �� �� '$���� � ,�`�� � `" � �, ` � <br /> 1 �rr. � ��� a; �,�a ��W �% <br /> � <br /> ���� .. i�t �.: °�n��'�'��x�'��aC�ro¢dti�arr��g�,;�r,t�R�n� "k''� '� • t�,.�', �,�,,�,s���W ��„�..4� � ���,it�.� e,a? a +'a ,� �,�.,�,� �'>��s .. <br /> �„ _�_, �� <br /> S stem 1 Summa Loads <br /> ��Ct�ittp�er�t.. � :1� ���►� �� t�' { ���,; � � t�� � <br /> 'C1 #"ivn � �. �`+C�� f� �ai���� <br /> Low E Builder Grade: Glazing-Builder Grade Low E 382.6 10,733 0 11,786 11,786 <br /> Windows&Sliding Door.33 U value .33 SHGC, u- <br /> value 0.33, SHGC 0.33 <br /> 11 J: Door-Metal-Fiberglass Core 37.8 1,927 0 657 657 <br /> 15A-10sffc-4:Wall-Basement,concrete block wall, R-10 116 493 0 0 0 <br /> foam board to floor, no framing, no interior finish, <br /> filled core,4'floor depth <br /> 15A-10sffc-8:Wall-Basement,concrete block wall, R-10 808 2,884 0 0 0 <br /> foam board to floor, no framing, no interior finish, <br /> filled core, 8'floor depth <br /> 12E-Osw:Wall-Frame, R-19 insulation in 2 x 6 stud 2166.4 12,522 0 3,006 3,006 <br /> cavity, no board insulation, siding flnish,wood studs <br /> 16B-44: Roof/Ceiling-Under Attic with Insulation on Attic 1343.9 2,513 0 1,567 1,567 <br /> Floor(also use for Knee Walls and Partition <br /> Ceilings),Vented Attic, No Radiant Barrier, Dark <br /> Asphalt Shingles or Dark Metal,Tar and Gravel or <br /> Membrane, R-44 insulation <br /> 21A-28: Floor-Basement, Concrete slab, any thickness, 2 1013 1,894 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 28'wide <br /> 20P-38: Floor-Over open crawl space or garage, Passive, 324 826 0 126 126 <br /> R-38 blanket insulation, any cover <br /> Subtotals for structure: 33,792 0 17,142 17,142 <br /> People: 6 1,200 1,380 2,580 <br /> Equipment: 448 1,532 1,980 <br /> Lighting: 0 0 0 <br /> Ductwork: 346 82 74 156 <br /> Infiltration:Winter CFM: 175, Summer CFM: 137 15,899 3,464 2,627 6,091 <br /> Ventilation:Winter CFM: 0, Summer CFM: 0 0 0 0 0 <br /> Exhaust:Winter CFM: 120, Summer CFM: 120 <br /> AED Excursion: 0 0 1,299 1,299 <br /> Humidification(Winter)6.21 gal/day : 2,277 0 0 0 <br /> System 1 Load Totals: 52,314 5,194 24,054 29,248 <br /> Ch :Fi u es �"-� � < <br /> � �w. � .. <br /> Supply CFM: 1,127 CFM Per Square ft.: 0.335 <br /> Square ft.of Room Area: 3,363 Square ft. Per Ton: 1,380 <br /> Volume(ft')of Cond. Space: 27,916 <br /> F ���ti.a <br /> ��.. �� ���.��� � � � ���,�. i� ��� <br /> . _. ,�A . , �4 , � <br /> Total Heating Required Including Ventilation Air: 52,314 Btuh 52.314 MBH <br /> Total Sensible Gain: 24,054 Btuh 82 % <br /> Total Latent Gain: 5,194 Btuh 18 % <br /> Total Cooling Required Including Ventilation Air: 29,248 Btuh 2.44 Tons(Based On Sensible+Latent) <br /> elaA�Jt�a Y��§ 4 i � u 1 Y4 .# �� � ,trv.. <br /> _ - .,. . _ . .,. ...� .. . ,,. . _ . ., .,, .. <m,. . �. ., _.. , . ,. . <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\...\Dean Johnson 1565 Maple PI.rh9 Thursday, September 05,2013, 12:43 PM <br />