<br /> Pro"ect Re ort
<br /> �r,. v �(Ii .aa 9 ` pia-0+iit�n �,�.qj� ;t n W 9 ,t � ".�',: x� �`°�,��Y`H'"---�" ,��
<br /> _ , F m, ,�. . , , � . . . . ,�. . . � ..:-r r� . a , .:. . _ .
<br /> Project Title: 1565 Maple PI Orono
<br /> Designed By: Todd Boyum
<br /> Project Date: Jan 8, 2013
<br /> Client Name: Dean Johnson
<br /> Client City: Medina, MN
<br /> Company Name: Sabre Plumbing& Heating
<br /> Company Representative: Todd Boyum
<br /> Company Address: 15535 Medina Rd
<br /> Company City: Plymouth, MN 55447
<br /> Company Phone: 763-473-2267
<br /> Company Fax: 763-473-8565
<br /> <1:/�, i Bv;x'ai�C .��"f'k` �"' =ak ra�Air,�u�..�u� s.li1 ��v�b;,.
<br /> Reference City: Minneapolis, Minnesota
<br /> Building Orientation: Front door faces East
<br /> Daily Temperature Range: Medium
<br /> Latitude: 44 Degrees
<br /> Elevation: 834 ft.
<br /> Altitude Factor: 0.970
<br /> Outdoor Outdoor Outdoor Indoor Indoor Grains
<br /> Drv Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference
<br /> Winter: -15 -12.38 100% 30% 70 27.02
<br /> Summer: 90 73 45% 50% 72 38
<br /> �h�Ck''�i tires � �„ =� �,��"',� � ' „ :
<br /> Total Building Supply CFM: 1,127 CFM Per Square ft.: 0.335
<br /> Square ft. of Room Area: 3,363 Square ft. Per Ton: 1,380
<br /> Volume(ft')of Cond. Space: 27,916
<br /> 57 �1�� ':� � i n� � ���Itu�'"o��r r '����'��i r w9 i t�,'-�; v�;" �F,��
<br /> �d. � .. . . . . , > . _: . . � „ t
<br /> Total Heating Required Including Ventilation Air: 52,314 Btuh 52.314 MBH
<br /> Total Sensible Gain: 24,054 Btuh 82 %
<br /> Total Latent Gain: 5,194 Btuh 18 %
<br /> Total Cooling Required Including Ventilation Air: 29,248 Btuh 2.44 Tons(Based On Sensible+ Latent)
<br /> �
<br /> �Ot@S�� �� ` 4����
<br /> � ,, n .
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> your design conditions.
<br /> C:\...\Dean Johnson 1565 Maple PI.rh9 Thursday, September 05,2013, 12:42 PM