My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info
Orono
>
Property Files
>
Street Address
>
M
>
Manor Circle
>
130 Manor Circle - 04-117-23-11-0025(Thru 2009-old PID#-0008)
>
Septic
>
Septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:06:45 PM
Creation date
7/10/2017 10:28:56 AM
Metadata
Fields
Template:
x Address Old
House Number
130
Street Name
Manor
Street Type
Circle
Address
130 Manor Cir
Document Type
Septic
PIN
0411723110025
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� o� <br /> O ',a� O <br /> ����-=��� CITY of ORONO <br /> �..�,;,._• -> <br /> ,� ��1 ���'� ti <br /> �'�'• 1���'-�. �.,�`� ,�, Municipal Offices <br /> ��- . <br /> \� r�;.:��"�`i� G Street Addross: <br /> '� , r4�i� 'ry Mailin�Addrou: <br /> �'Eg�I�g 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: 3 �°��� �"'���S o^ � Address: �3 O hq�o� C;��(� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every rivo years. <br /> The on-site se�vage treatment system at the above address has been inspected and appeazs to fall into the categories checked belo�v. <br /> sYs��corrFo�� ri-3�: 3 <br /> 1 "CODE SYSTEM" An ISTS which meets ail the locatioq design and construction standards ofthe currrnt Orono Municipal Code. <br /> 2 "CONLPLIANT SYST'EM" An ISTS which does aot meet ail the locatioq design and conshvction standards ofthe cunmt Orono Municipal <br /> Code but does meet the three foot separation nquirement,and which is not failing or an imminecrt threat to public health or safety. <br /> 3� "NON-CONIPLIANT SYST'EM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the locatioq design,or cocutructioa standard4 of the cucrecrt Orono Vlunicipal Code and which is failing for any reason;and <br /> any ISTS with less than three faet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> T.4NK CONDITION(5-10): s <br /> T;ink inspection indicates: <br /> QPumpout not needed at this time. <br /> 6 Tank must be pumped out this year (city code requires tanks to be pumped out every 3 yeazs. Tank was last pumped s-I�-0 1 � <br /> 7 Solids accumulation in tanks is at a critical a critical levet. Tanks should be pumQad out as soon as possible. <br /> 8 System is dischazging to tha surface. Tanks must be pumped out within 48 hours to eliminata surface discharge. <br /> 9 Inspaction risers missing-tantcs could not be inspected Inspection tisees(4"dia pipe)must be installed in each tank at next pumpout If tanks <br /> lu�•a nut bean pumpad out within the last three years,they should be pumped out now. <br /> 10 InSpaction pipe is locatad directly over tank ba�le(doas not give ucurate measuremrnt of solids ucumulation). If tanks have not bern pumpad <br /> out within tha lazt t}vee years,they should be pumped out now. <br /> DRAIlv'FIELD CONDITION 11-1� : \� <br /> 11 DrainField is dry,no surfacing evident <br /> 1� Some evidrnce of surfacing,not critical yet <br /> 13 Ursiafield is saturatad and visibly discharging untreated e8lurnt to the surface. Contact the City Inspector ixnmediately.Repaus must be <br /> complttad wiUun 90 days. <br /> 1� Drainfield e�ctant and condition unknown. <br /> CONIl�i1ENTS: S s�-e� ;S no�- co��1-���,� �vc ru \a�K cl� 3 -�oofi sc er��,o� <br /> b��c�� �-o� ��- Scsso�� �-q�e�i-tib� ��� bat'ra . �� t�P ��.cs Rep\�c� 6� ��. 31 ieia , <br /> � -�b-� � �a.� � <br /> Date of Inspection Septic System Inspector ' <br /> Note: In tha e�rnt that this inspection repoR is used to satisfy the requirements for a mortgage ot other transfa of property,be advised that this repoR does not guararttee <br /> or certify that an e�sting systzm wiil continue to function proQerly,but is merely an opinion of the adequacy of the system under cucrent conditions ba�ed on the availabla <br /> informatioa <br />
The URL can be used to link to this page
Your browser does not support the video tag.