My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-00389 -temp COO/new structure
Orono
>
Property Files
>
Street Address
>
L
>
Lyric Avenue
>
3472 Lyric Avenue - 17-117-23-43-0074
>
Permits/Inspections
>
2017-00389 -temp COO/new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:42:24 PM
Creation date
6/28/2017 11:02:57 AM
Metadata
Fields
Template:
x Address Old
House Number
3472
Street Name
Lyric
Street Type
Avenue
Address
3472 Lyric Avenue
Document Type
Permits/Inspections
PIN
1711723430074
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• � Pro ect Summar�/ Job: <br /> , � 7 Date: 1-1&17 <br /> _ _ Entire House By: Curt Smlth <br /> Joei Smith Heating &A/C Inc. <br /> 13915 Lincoln St.NE,Suite E,Ham Lake,MN 55304 Phone:763.792.1066 Fax:763.717.3949 Email:curt.jsrrrithhvac@gmail.com Web:ww�v.jsmithhvac.com <br /> � • ' • • <br /> For: Joshua Markum Builders <br /> 3472 Lyric Avenue, Orono, MN <br /> N otes: <br /> � - • • • <br /> Weather: Minneapolis-St. Paul, MN, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 20 °F Outside db 93 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 90 °F Design TD 18 °F <br /> Daily range M <br /> Relative humidity 50 % <br /> Moisture difference 27 gdlb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 39214 Btuh Structure 16684 Btuh <br /> Ducts 2088 Btuh Ducts 1796 Btuh <br /> Central vent (162 cfm) 15545 Btuh Central vent (162 cfm) 3109 Btuh <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 56846 Btuh Use manufacturer's data n <br /> Rate/swing multiplier 0.98 <br /> InflltretlOn Equipment sensible load 21157 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Tight <br /> Fireplaces 1 (Tight) Structure 2127 Btuh <br /> Ducts 170 Btuh <br /> Heating Cooling Central vent (162 cfm) 2912 Btuh <br /> Area(ftz) 3495 3495 Equipment latent load 5208 Btuh <br /> Volume(ft3) 21777 21777 <br /> Air changesJhour 0.10 0.05 Equipment tota! load 26365 Btuh <br /> Equiv.AVF(cfm) 36 18 Req. total capacity at 0.70 SHR 2.5 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make RUUD Make RUUD <br /> Trade Trade <br /> Model R95P07 Cond RA1330 <br /> AHRI ref no. Coil <br /> AH R I ref no. <br /> Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER <br /> Heating input 70000 Btuh Sensible cooling 19880 Btuh <br /> Heating output 68000 Btuh Latent cooling 8520 Btuh <br /> Temperature nse 77 °F Total cooling 28400 Btuh <br /> Actual air flow 827 cfm Actual air flow 827 cfm <br /> Air flow factor 0.020 cfm/Btuh Air flow factor 0.045 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.81 <br /> Bdd/Italic values have been manuelly overrldden <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> �_ �' WC19F1tSOft' Right-Suite�Universal 2012 12.0.04 RSW1877 2017-Jan-16 10:55:46 <br /> Page 1 <br /> '`�C�` C:\Users\Srrdth Heating\Documents\Wrightsoft HVAC\JMB-Orono.rup Calc=M,18 Front Door faces: <br />
The URL can be used to link to this page
Your browser does not support the video tag.