2015-01520 - new structure
Orono
>
Property Files
>
Street Address
>
L
>
Lyric Avenue
>
3438 Lyric Avenue - 17-117-23-43-0077
>
Permits/Inspections
>
2015-01520 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:42:28 PM
Creation date
6/28/2017 9:23:36 AM
Metadata
Fields
Template:
x Address Old
House Number
3438
Street Name
Lyric
Street Type
Avenue
Address
3438 Lyric Avenue
Document Type
Permits/Inspections
PIN
1711723430077
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, � <br /> w <br /> m <br /> � � <br /> �, - <br /> ;, 'o °' <br /> Q z - <br /> � <br /> � <br /> > <br /> o �, � <br /> � � = V � <br /> � <br /> y � 0� � � <br /> MINIMUM 3"PVC GAS TIGF7T PIPE. <br /> C �� 0 � (J� <br /> � �� p� N <br /> RADON VENT PIPE TERMINATED AT � 6�= c� � <br /> m R 3� � � <br /> c u " �u @ E <br /> s Q <br /> SPACE PROVIDED FOR FUTURE � Q� �U = <br /> INSTALIATION OF A FAN <br /> -MIN 24"DIAMETER CENTERED ON TF1E <br /> AXIS OF THE VENT STACK <br /> -MIN VERTICAL DISTANCE OF 3 FEET � <br /> N L <br /> INSTALL L1VE OUTLET IN AiTIC NEP.R � R � <br /> NMERE FUTURE FAN MAY BE WSTALLED 6� U1 <br /> � H � �S <br /> - L � �F- <br /> - C� N <br /> I'-6" 1'-6° . � � i'' c O <br /> U Q �'� �; � <br /> INSTALL LABEL READING'RP.DON � c � � <br /> � REDUCTION SYSTEM'ON TFIE VENT � CO O � Q � <br /> - PIPE AT EACH FLOOR AND IN — O ya <br /> - ACCESSIBLEATTICS.(AF103.4.5) � � �_� <br /> � � N N c�'N <br /> Y L <br /> W � � �� � <br /> � � O c � � N <br /> Oc m p c N <br /> � y � y � � <br /> = O � �� c a�i <br /> = 6�U � � <br /> 2'- � ��N�@ @ <br /> O GA E J � � 3 � <br /> GRASPABLE NANDRAIL TYPE I � =y N@ O <br /> Z OVAL 2Yp"WIDEX I J�q'F11GF1 � WSTALLPIPEASSTRAIGHT DROP ED I'-6° � � �� 3 � � <br /> RACKETS @ 4'O.C. io n AS POSSIBLE TO F1ELP PLATE t1 IGt1T � � = 3 � � � <br /> � �� - o CONDUCTIVE FLOW ELBONS � � � 3 O�N � � <br /> � � � AREA ALLOWED BUT SHOULD _ y � � @ >,N <br /> � � � � BE AVOIDED IF POSSIBLE p � �� y � <br /> � T 5 � _ � � � <br /> 3/4"PLWJOOD NAILED BEfVJEEN � <br /> m m STRINGER 4 FLR SYSTEM O � ��� � � � <br /> -CUT FWSFI WITH BOTTOM OF �� � s 0 T� <br /> STRIN6ER ��(� O F � 6'�� <br /> 4-TIM ERLAND STPoNGERS V 1 � <br /> T� � m <br /> 3/a'OSB Q j � N p ca � C9 <br /> � U N U �J <br /> "NOTE: r31 I.5.31 TREAD DEPTh1 J U � �R 'a � � <br /> 2X4 Tt1E MINIMUM TREAD DEP(H SHALL BE 10 INCIIES(254 MM). THE TREAD DEPiF1 SHALL SEAL ALL JOINTS,CRACKS,OR W �W '-' S � O � <br /> BE MEASURED HOWZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST OTHER OPENINGS WITF1 y W � �� � U <br /> PROJECTION OF ADJACEM TRFADS AND AT A RIGFIT ANGLE TO Th1E TREAD'S LEADING `� POLYURETFIANE CAULK OR � � � � � E � J <br /> - EDGE. TNE GREATEST TREAD DEP(H WITH IN ANY FLIGHT OF STAIRS SHALL NOT IXCEED � N EIASTOMEPoC SEALANT - <br /> TNE SMALLEST BY MORE THAN�a"(9.5 MM). IMNDER TREADS SHALL HAVE A MINIMUM - � P.CCORDING TO <br /> TREAD DEPTFi OF I O MCh1E5(254 MM)MFASURED AS ABOVE A POIM 12"(305 MM) � MANUFACTURER'S <br /> FROM THE SIDE WYtERE TF1E TREADS ARE NARKOWEIZ. WINDER TREADS SFIALL h1AVE A � RECOMMENDATIONS IN � <br /> MINIMUM TREAD DEPTH OF 6"(I 52 MM)AT ANY POMT. WITNIN ANY FL16HT OF STAIRS, AF 103.4.I TFIROUGFI = <br /> TFiE LARGEST WINDER TRFAD DEPfH AT THE I 2"(305 MM)WALK LMES SFIALL NOT AF 103.4.5 � (� <br /> EXCEED TFiE SMALLFST BY MORE THAN%�(9.5 MM). � W <br /> J = <br /> 07 W <br /> INSTALL VENT PIPE(AF I03.6.I)INTO m � <br /> MIN.6-MIL,OR 3-MIL CRO55 EALE SUBFLOOR 6A5 PERMEABLE IAYER � � <br /> LAMINATED POLI'ETFIYLENE SHALL BE SUMP (AF 103.2)OR DRAIN TILE LOOP Q <br /> IAPPED I2"AND PLACED BELOW TF1E BEFORE SLAB IS CPST � Z <br /> SIAB AND ON TOP OF THE GAS <br /> PERMEABLE LAYER(AF I 03.3) <br /> -FIT POLYETFIYLENE LAYER CLOSELY TO <br /> PENEfRATIONS(AF103.3) <br /> P LA N T O B E B U I LT W I T H 2 0 I 5 Sw�DDI TO A 3 O�FIYLENE� � <br /> N O � <br /> MN ENEI�GY AND I�ESIDENTIAL �� � � <br /> o � <br /> @ � s <br /> � � N <br /> � � C N C <br /> BU I LDI NG CODE J � � � ? <br /> Scale: I/4" = I'-O" <br /> Fin Sa Ft: <br /> SECTIONS 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.