Laserfiche WebLink
� °� <br /> o : o <br /> -��=4�:�w- c ITY of ORONo <br /> � �;.. 1 <br /> �r��� - ,., <br /> � ,��� . �� _ <br /> ,\'�+�� R� ,�,�, MunicipalOffices <br /> 'R' :���`.`�_ <br /> i;�;-� �r G asa-a4q-y6o 0 <br /> � Street Address: Mailing Address: <br /> �`�1��Hp4'� � 2750 Kelley Parkway P.O. Box 66 <br /> Orano, MN 55356 Crystal Bay, MN 55323-0066 <br /> � (__. ��,�-._ v <br /> To Current Owner: Address: �a�� � �- <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM"`An 7STS wluch meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS wluch does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet t�e three foot separation requirement or two foot requuement for systems installed 1996 or earlier,and <br /> which is not failing or an ianunent threat to public health or safety. <br /> �"NON-COMPLIANT SYSTEM" A prolubitcd ISTS;an ISTS lceated within a designated 100-year flood plain,any ISTS which may <br /> or may rtot meet all�e location,design,or construction stan�rds of the current Orono Municipal Code and which is failing for any <br /> reason;and any LSTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDTTION(5-7): � <br /> ��inspection indicates: <br /> Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �-10-OZ ). <br /> Make sure septic tanks are pumped through manhole and not through white insaection pipes. This allows for the proper <br /> cleaning Keea water softner and iron filter dischar¢e out of seatic svstem to arolon¢life of drainfield. Ask aumaer to test <br /> alarm float to verifv alarm is still workins in vour house. The alarm warns owner that senta¢e is about to backua into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not b�n pumped out within the last three years,they should be pumped out now. <br /> D IELD CONDITION 8-10 : � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield.is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: A��:�.t�� ;s r��- ���P�;�.-� �= r�.�s�- �� c���<< <br /> b! �-Z..-��-2.010 � -- - <br /> ��Z-`-1--�'� �� <br /> Date of Inspection Matt Bolterman- Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or othea transfer of property,be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adcquacy of the system under current <br /> conditions based on the available information. <br />