My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
L
>
Lyman Avenue
>
1280 Lyman Avenue - 35-118-23-34-0014
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:59:12 PM
Creation date
6/26/2017 2:14:09 PM
Metadata
Fields
Template:
x Address Old
House Number
1280
Street Name
Lyman
Street Type
Avenue
Address
1280 Lyman Avenue
Document Type
Septic
PIN
3511823340014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� °� <br /> 0 0 <br /> -�}��-:- CITY of ORONO <br /> ; <br /> r� '��;r�`;;3-� _ �+ <br /> \�� x J`'r, �,l�I MIIIl1C1� ��ICCS <br /> \,�, �'.I>.�:�-a� a19^P V <br /> � ��'�� -.;, �'�.� Street Address: �152i.—a49—�160 0 Mailing Address: <br /> '�'�'Hp4' 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> � To Current Owner: Address: I��Q L�Y``�� �/t <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the ca#egories checked below. <br /> S STEM CONFORMIT'Y 1-3 : 1 <br /> 1 "CODE SYSTEM"An ISTS which meets all thelocation,design and wastruction standards ofthe current Orono ivtunicipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which dces not meet all the locafion,design and construcdon standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is aot failing or an iu�inent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited IST'S;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not mcet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and�e limiting soil characteristics. <br /> TANK CONDTI'ION(5-71: � <br /> Tank inspection indicates: <br /> 5� Pumpout not needed at this time. <br /> 6 - Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped 10-13�b3 �. <br /> 11'�ake sure seatic tanks are aumued throush manhole and not throu¢h white inscection aiaes. This allows for the uroaer <br /> cleaninE. Keea water softner and iron filter dischar¢e out of seatic svstem to arolon¢life of drainfield. Ask aumner to test <br /> alarm float to verifv alarm is still workin¢in vour house. The alarm warns owner t6at seata¢e is about to backua into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> - tanks have not been pumped out within the lasf three years,they should be pumped out now. <br /> D IE D_CQ1�IDITTI.OI�i �A : _ __.. ___ ' <br /> Drainfield is dry,no surfacing evident. <br /> _.. ___. ._. __. <br /> _. _ ._. <br /> 9 • me�+ideneerofsurfacing,nb'C�riUca1 yef" <br /> 10 Drainfield.is saturated and visibly dischazging untreated ef�luent to the surface. Contact the City Inspector <br /> __ _.... <br /> --irr►inediatelp:Repairstnust����6rhpteted"witliin 90�days. <br /> __ <br /> CONIlYIEI�iTS: .. _../M o.�.� :_.__. . __ � S��1�t, -}�n�IC� <br /> � �5. . �["'��- _ ��C r� _d c. }1t C. _ <br /> �t�o<< vl� - <br /> ��Z`��'�y �``� ��'� <br /> Date of Inspection Matt Bolterman- Septic System Inspector <br /> Note: In the evwt that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that ihis report dces <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> condidons based on the available information. <br />
The URL can be used to link to this page
Your browser does not support the video tag.