My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010-01172 septic
Orono
>
Property Files
>
Street Address
>
L
>
Lyman Avenue
>
1190 Lyman Avenue - 35-118-23-43-0034
>
Septic
>
2010-01172 septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:59:45 PM
Creation date
6/22/2017 2:00:35 PM
Metadata
Fields
Template:
x Address Old
House Number
1190
Street Name
Lyman
Street Type
Avenue
Address
1190 Lyman Avenue
Document Type
Septic
PIN
3511823430034
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> ��E ���t . <br /> � Design Flow and Soil Worksheet N°�E 5` <br /> Minnesota Pollution �'r" ' � <br /> Control Agency X�'�..,�`.�,'' <br /> � 1. AVERAGE DESIGN FLOW: <br /> Note: The estimated design flow is considered a peak <br /> A. Estimated Design Flow(GPD): 600 �Pd flow rate induding a safety factor. For long term <br /> performance,the average daily flow is recommended to <br /> � or Measured Flow(GPD):flow times safety factor be<60%of this value. <br /> � gPd X � �SPd <br /> � Design F(ow: 600 Gallons Per Day(GPD) System Type <br /> B. Septic Tank capacity: 2500 Gallons �TY�I ❑Type II ❑Type III ❑Type N ❑rype v <br /> � Number of Septic Tanks or Compartments: 2 Effluent Screen&Alarm? Yes <br /> � � <br /> � Table 1-Design Flow(Gallons Per Day) Table II-Septic Tenk Capatity <br /> Number of Classification of Dweliing Number of Septic Tank Liquid Atinimum Capacity with Garbage Disposal and/or <br /> Bedrooms 1 �� 11 tll �� gedrooms Capacities(Galtons) Sewage Pumped to Tank" <br /> � 2 or less 300 225 180 : 3 or less 1,000 1,500 <br /> 3 450 300 218 <br /> 4 600 375 256 4 or 5 1,500 2,250 <br /> 5 750 450 294 • 6 or 7 2,000 3,000 <br /> � _ 6 900 525 332 _ 8 or 9 2,500 3,750 <br /> 'Flows for Classification IV dwellings are 60 percent of the values as determined for Classification I, II or III systems. <br /> 2. SITE EVALUATION: <br /> � Teuture Group <br /> A. Depth to Limiting Layer: 30 inches 2.5 ft �;i rexcure Group N <br /> � Type of Soil Treatment and Dispersal Area Caarse Sa�d 1 <br /> B. nhedlum Sand 2 <br /> �Trenches �Bed �At-G2de �Mound Fine Sand 3 <br /> Coarse Loamy Sand 4 <br /> Medium Loamy Sand 4 <br /> � Type of Distribution Ffne Loamy Sand 5 <br /> C_ Very Fine Loamy Sand 5 <br /> �Gravity Distribution �Pressure Distribution-Level �Pressure Distribution-Unlevel Coarse Sandy loam 6 <br /> Medium Sandy toam 6 <br /> Ff�e Sandy Loam 7 <br /> � Very Fine Sandy Loam 7 <br /> D. Landscape Position: Shoulder �oam 8 <br /> Silt�oam 9 <br /> Clay,Loam 10 <br /> E. Estimated Percent Land Slope: 5.0 % Silty Ciay Loam �o <br /> � Sandy Clay Loam 70 <br /> or Rise Run sandy t ay �t <br /> F. Co(cu(ated Slope = � .- � x 100= � ctay ii <br /> � <br /> � <br /> � <br /> � <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.