Laserfiche WebLink
Septic Check <br /> 6074 Keystone Rd s2a9a3-2a4� <br /> Milaca, MN 56353 Fax;320-983-2151 <br /> PROPERTY/NFORMAT/ON <br /> Brian Palmer <br /> Location:1190 Lyman Ave <br /> Orono <br /> TaxID:35-118-23-43-0 <br /> Ma�i To: Brian&Julia Palmer <br /> 1190 Lyman Ave Use:Residential,Single Family <br /> Orono,MN System Design Flow:600 <br /> 55391 GENERAL SYSTEM TYPE:STAND Res 1 NO TEST <br /> Owner:Brian 8�Julia Palmer <br /> Foltl � � • � � Foltl <br /> Here Here <br /> lnspected:08/11/2015 - Inspection Type:ROUTINE - Correction Status:No corrections needed <br /> Company: Work Performed By: Submitted 08/19/2015 by: <br /> Septic Check Torrey Boser Angie Stafford <br /> COMMENTS&GENERAL/NSPECT/ON NOTES <br /> No Deficiencies Noted <br /> GENERAL SITE&SYSTEM COND/T/ONS <br /> The General Site and System Conditions were: Fully Inspected <br /> _. __ _ <br /> __ _ _ __.. <br /> __. _ <br /> Components accessible for service: YES <br /> _ __ __ __ --._. ---_ _ ----- - --- ------- ----- -______ _-— <br /> All required service performed(if no-specify omitted inspection items in notes): YES <br /> - ------ -- - -- --- --- -_....-- - -- — -_._.- .____--_ _. -- <br /> Surfacing effluent from any component(including mound seepage): NO <br /> -- --- _ .. -------- ------ __ ----._ _-- ---- <br /> Components appear to be watertight-no visual leaks: YES <br /> --_ --- —-- ------ _-- — .._.- ---- -------------- - <br /> Improper encroachment(structures/impervious surtaces);cover;or settling problems observed: NO <br /> ONSITE SEWAGE SYSTEM INSPECTION DETA/L <br /> ,� <br /> Manufacturer: Local Manufacturer Model:Concrete <br /> This component was: Fwiy inspected <br /> Effluent level within operational limits(if NO explain in comments): YES <br /> All required baffles in place(N/A=No baffles required): YES <br /> Compartment 1 Scum accumulation(Inches,if other specify): 2" <br /> Compartment 1 Sludge accumulation(Inches,if other specify): a" <br /> Pumping recommended: NO <br /> ii� <br /> Manufacturer: Local Manufacturer Model:Concrete <br /> ThiS COmpOnBnt WaS: Fully Inspected <br /> Effluent level within operational limits(if NO explain in comments): YES <br /> All required baffles in place(N!A=No baffles required): YES <br /> Compartment 1 Scum accumulation(Inches,if other specify): 1" <br /> Compartment 1 Sludge accumulation(Inches,if other specify): 2" <br /> Pumping recommended: NO <br /> ��i <br /> Manufacturer. Local Manufacturer Model:Concrete <br /> ThiS COfnpOnent wBS: Fully Inspecled <br /> Compartment 1 Scum accumulation(Inches,if other specify): o <br /> Compartment 1 Sludge accumulation(Inches,if other specify): o <br /> Pumping recommended: NO <br /> Manufacturer:Orenco <br /> This component was: Funy inspecied <br /> Controls functioning: YES <br /> Tested gallons per minute flow: N/A <br /> ReportlD:459981 View inspection reports online at www.onlinerme.com Page 1 of 2 <br />