My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
L
>
Lyman Avenue
>
1150 Lyman Avenue - 35-118-23-43-0029
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:59:43 PM
Creation date
6/22/2017 12:31:57 PM
Metadata
Fields
Template:
x Address Old
House Number
1150
Street Name
Lyman
Street Type
Avenue
Address
1150 Lyman Avenue
Document Type
Septic
PIN
3511823430029
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, . <br /> Mr. Donald C. Mogen <br /> Page 2 <br /> August 2, 1978 <br /> Results <br /> The log of soils encountered in the borings is shown on the <br /> attached soil boring log sheets. Groundwater was not encountered in <br /> the borings. <br /> Percolation tests indicated the following percolation rates in ' <br /> minutes per inch (mpi) : <br /> Surface <br /> Test No. Elevation Hole Depth Soil at Test Depth Rate, mpi <br /> P-1 90.0 33" siity ciay (cL) 120.0 <br /> P-2 87.7 33" Silty Clay (CL) 30.0 <br /> P-3 89.3 33" Silty Clay (CL) 40.0 <br /> P-4 86.8 30" Sandy Clay (CL) 18.5 <br /> P-5 90.8 33" Silty Clay (CL) 48.0 <br /> P-6 87.6 30" Sandy Clay (CL) 30.0 <br /> Recommendations <br /> Based on the results of the soil borings and the percolation <br /> tests, it is my opinion that the soil and water condit=ons on the <br /> site are suitable for the installation of an individual sewer system <br /> with a drainfield as the soil absorption unit. It is suggested that <br /> the drainfield be designed using the average percolation rate of <br /> 47.7 mpi. <br /> For a three bedroom house constructed on the site, the recommended <br /> drainfield absorption area should be 915 square feet. Only trench <br /> bottom area is considered as being effective. With standard two foot <br /> width trench, 458 linear feet of tile line would be required. <br /> We recommend that two septic tanks be used at the site. The <br /> first should have a capacity of at least 900 gallons and the second <br /> a capacity of from 500 to 900 gallons. Recommended locations are <br /> shown on the attached figure. Detailed plans should be prepared by <br /> your contractor. <br /> Topographically, it is apparent that a slight amount of levelling <br /> will be required at the drainfield area. You indicated that the proposed <br /> house will be a rear walkout, Therefore, the secondary drainfield <br /> site is assumed to be simply expansion of the primary site to the rear <br /> of the house. This allows for gravity fall from basement facilities. <br /> Based on the results of the soil borings, it appears that ground- <br /> water levels will not be a problem at the site. <br />
The URL can be used to link to this page
Your browser does not support the video tag.