2015-01242 - retaining wall
Orono
>
Property Files
>
Street Address
>
L
>
Lydiard Circle
>
2595 Lydiard Circle #1 - 20-117-23-11-0040
>
Permits/Inspections
>
2015-01242 - retaining wall
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:48:26 PM
Creation date
6/21/2017 1:23:09 PM
Metadata
Fields
Template:
x Address Old
House Number
2595
Street Name
Lydiard
Street Type
Circle
Address
2595 Lydiard Circle
Document Type
Permits/Inspections
PIN
2011723110040
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
d <br /> SCHIMNOWSK1 ENGINEERS <br /> CRITERIUM-SCHIMNOWSKI ENGINEERS <br /> 161 DUNBAR WAY <br /> MAHTOMEDI,MN 55115 <br /> TEL 651779-7700 <br /> FAX 651779-7114 <br /> www.criterium-schimnowski.com <br /> October 14, 2015 <br /> (Revised October 28, 2015) <br /> John Leupke <br /> 2595 Lydiard Circle <br /> Orono, MN 55331 <br /> RE: Boulder Retaining Wall Evaluation <br /> 2595 Lydiard Circle <br /> Orono, MN <br /> Project No. 15-1811 <br /> Dear Mr. Leupke: <br /> This letter is being sent per your request regarding the recently constructed boulder retaining walls at the <br /> above address. This evaluation is based on the site visit I performed on October 13, 2015. <br /> The construction of the retaining walls appears to be structurally stable and in general conformance with <br /> boulder retaining wall and construction industry standards. The walls were constructed with stone of <br /> sufficient size and setback. Other typical construction details such as use of drainage elements and filter <br /> fabric also appeared to be followed correctly. As is normal for boulder retaining walls of this type, some <br /> wall movement and soil settlement should be expected. I recommend that concentrated areas of surface <br /> water should also be directed away from the walls. Numerous photos were taken for documentation, <br /> some of which have been provided as part of this report. <br /> Additionally, the soil conditions at the site met my initial soil bearing capacity requirement of 2000 pounds <br /> per square foot (psf). <br /> This evaluation was performed using the design guidelines presented in the third edition of the "Design <br /> Manual for Segmental Retaining Walls" (DMSRW) published by NCMA in 2009. Direct all surface <br /> drainage away from the retaining walls. If soil conditions, proposed layouts, or other design parameters <br /> vary from that assumed, a revised analysis might be needed. Please call me if you have any questions or <br /> need more information. Thank you. <br /> Sincerely, <br /> Paul Schimnowski, PE <br /> LICENSED <br /> PROFESSIONAL <br /> ENGINEERS <br /> HOME&BUILDING INSPECTIONS <br /> STRUCTURAL EVALUATIONS /' <br /> ASSOCIATION RESERVE/TRANSITION STUDIES Z5 q5 L1drarD� C/a/4- <br /> .. <br /> RESIDENTIAL/COMMERCIAL <br /> RETAINING WALL DESIGN&EVALUATIONS 2.015 — 01242 <br /> gelemi l Wall 1- Crivrway ryl ufitorvf— <br />