My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00021 - attached garage
Orono
>
Property Files
>
Street Address
>
L
>
Luce Line Ridge
>
135 Luce Line Ridge - 31-118-23-34-0007
>
Permits/Inspections
>
2016-00021 - attached garage
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:31:21 PM
Creation date
6/20/2017 10:53:59 AM
Metadata
Fields
Template:
x Address Old
House Number
135
Street Name
Luce Line
Street Type
Ridge
Address
135 Luce Line Ridge
Document Type
Permits/Inspections
PIN
3111823340007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�3� �. � L��-Q ���� <br /> Mc�ttson � Bassett Creek Business Center <br /> MQCC�O(1QIC� 901 North 3rd Street, #100 <br /> Y(�t ��-3 r,+., <br /> Minneapolis, MN 55401 <br /> ; <br /> struCtural 612-827-7825 voice <br /> engineers � 612-827-0805 fax <br /> April 18, 2016 <br /> Patrick Doolittle <br /> 330 Wolf Point Trail <br /> Long Lake, MN 55356 sent via email.�mcpeteexcel�a7yah00%com <br /> Re: Cantilevered Brick Gable <br /> 135 Luce Line Ridge Road <br /> Maple Plain, MN 55359 <br /> MMY Project#_ 16172 <br /> Dear Patrick: <br /> I visited the single family residence at 135 Luce Line Ridge Road, Maple Plain, MN on April 8, 2016 to <br /> observe the structure, as you requested. <br /> Our scope of work includes the one site visit that was conducted and the preparation of this report and <br /> plan,which contains our observations and recommendations. It is our understanding that we are involved <br /> in this project to evaluate and to provide design details for the cantilevered gable with brick veneer at the <br /> south gable of the'garage. <br /> Descri�tion of Structure <br /> The building is a brick veneered wood-framed structure with a basement. The building was built in 1987 <br /> and is typical of the construction of that period. A fire within the last year destroyed the garage and a <br /> portion of certain elements of the main house structure. <br /> 06servations <br /> The structure is largely rebuilt since the fire. Garage walls and the roof have been reframed at the most <br /> burnt portions utilizing the existing footings and foundations.The garage roof has been construded <br /> using pre-fabricated roof trusses provided by Wisconsin Truss Inc. Shop drawings were available on site. <br /> The proposed cantilevered brick gable is not yet installed, however,the main supporting elements,the <br /> steel angle, bent brackets, and beam have been instalfed. <br /> Opinions and Recommendations <br /> The additional loading at three interior trusses, resulting from the cantilever beam's backspan,was <br /> calculated.The loads were provided to the original truss manufacturer for the purpose of re-evaluating <br /> them based on the new loading.The evaluation determined that the existing trusses have enough <br /> capacity for bearing the additional loads. Refer to Appendix 1 for the updated calculations provided by <br /> the truss manufacturer,Wisconsin Truss,Inc. <br /> The existing 6x6 beams, steel angle, steel angle bracket and trusses can remain. However, parts of the <br /> assembly need to be supplement and/or modified.Refer to attached sheets Sl-S4 and the structural <br /> notes that follow for a complete description and methodology of recommended repairs. <br />
The URL can be used to link to this page
Your browser does not support the video tag.