My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010-00572 - new septic
Orono
>
Property Files
>
Street Address
>
L
>
Luce Line Ridge
>
115 Luce Line Ridge - 31-118-23-34-0006
>
Septic
>
2010-00572 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:31:16 PM
Creation date
6/19/2017 9:28:39 AM
Metadata
Fields
Template:
x Address Old
House Number
115
Street Name
Luce Line
Street Type
Ridge
Address
115 Luce Line Ridge
Document Type
Septic
PIN
3111823340006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� OSTP Pump Selection Design <br /> Minnesota Pollution UNIVERSITY <br /> �ro� �� Worksheet OF MINNESOTA `'�-� <br /> 1. PUMP CAPACITY <br /> A. Pumping to Gravity or Pressure Distribution: O Graviry O Pressure <br /> 1. If pumping to gravity enter the gallon per minute of the pump: �GPM <br /> 2. If pumping to pressure,is the pump for the treatment system or the collection system: <br /> �Treatment System 0 Collection System <br /> 3. If pumping to a pressurized treatment system,what part or type of system: <br /> m Soil Treatment Unit pMedia Filter p Other <br /> 4. If pumping to a pressurized distnoution system: 36.0 GPM <br /> (Line 11 of Pressure Distribution or Line 10 of Non•Level or enter i(Collection System) <br /> 2. HEAD REQUIREMENTS <br /> i ueasmwrc system <br /> 3. Elevation Difference 10 ft ���"T�d�� <br /> between pump and point of discharge: •�" � <br /> NOTE:IF system is an individua(subsurface senroge treatment <br /> sw��"`"�` <br /> system,complete steps 4-9. If system is a Collection System, �pae eievauon%�, <br /> skip steps 4,5, 7 and 8 and go to Step 10. d� <br /> 4. Distribution Head Losr. �ft ----------------------------- <br /> 5. Additionat Head Loss: �ft(due to special equipment,etc.) <br /> Distribution Head Loss nctaon ss m astu pe per <br /> Gravity Distribution = Oft C=130 <br /> Nominal Pipe Diameter <br /> Pressure Distribution based on Minimum Average Head <br /> Value on Pressure Distribution Worksheet: Gp�� 1 1'/� 13�t 2 3 <br /> Minimurr Aversa e Head Distribution Head Loss 10 9.11 3.08 1.27 0.31 --- <br /> 1ft 5ft 12 12.77 4.31 1.78 0.44 <br /> 2ft 6ft '-' <br /> 5ft �pft 14 16.99 5.74 2.36 0.58 -- <br /> 16 -- 7.35 3.03 0.75 0.10 <br /> 6. A. Supply Pipe Diameter. 2.0 in �g � 9.14 3.76 ,0.93 0.13 <br /> B. Supply Pipe Length: 40 ft 20 -- 11.11 4.58 1.13 0.16 <br /> 25 - 16.78 6.92 1.71 0.24 <br /> 7. Based on Friction Loss in Piastic Pipe per 100ft fram Table I: 30 w --- 8.69 2.39 0.33 <br /> Friction loss= 3.32 ft per 100ft of pipe 35 -- -- 12.90 3.15 0.44 <br /> 40 -- --- 16.52 4.07 0.57 <br /> g, Determine Equivolent Pipe Length from pump discharge to soil dispersat 45 � __ _� 5.07 0.70 <br /> area discharge point. Estimate by adding 25%to supply pipe length for <br /> fitting loss. Supply Pipe Lenqth(5.8) X 1.25=Equivalent Pipe Length 5Q - --- -- 6.16 0.86 <br /> 55 � __ __ 7.35 1.02 <br /> 40 ft x �.25 = 50.0 ft 60 -- --- -- 8.63 1.20 <br /> 9. Calculate Supply Friction Loss by multiplying Friction Loss Per f00ft (Line 6)by t 65 � "' -- 10.01 1.39 <br /> �� 11.48 1.60 <br /> Supply Friction Loss= "" � '- <br /> 3.32 ft per 10oft X 50.0 ft - 100 = 1.7 ft <br />
The URL can be used to link to this page
Your browser does not support the video tag.