My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
L
>
Luce Line Ridge
>
115 Luce Line Ridge - 31-118-23-34-0006
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:31:18 PM
Creation date
6/19/2017 9:16:55 AM
Metadata
Fields
Template:
x Address Old
House Number
115
Street Name
Luce Line
Street Type
Ridge
Address
115 Luce Line Ridge
Document Type
Septic
PIN
3111823340006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
On the North Shore o f <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT � POST OFFICE BOX 66 <br /> 1335 S. Brown Rd. <br /> � � � Crystai Bay, MN 55323 <br /> 473-7357 <br /> OWN E R �A'77SP S �► �l CSDn ADD R ESS //� ��P LI/'�_� <br /> PERMIT NO.'S. � DATES �g� CONTRACTORS <br /> City Ordinance No. 210 requi►es that each on�ite sewage treatment system in Orono be inspected on a regular basis.The on3ite sewage <br /> treatment system at the above address has been inspected and appears to fall into the category checked below. <br /> (This is ,�►an existing system ❑ new construction) <br /> �� Meets or exceeds current City standards in atl respects relating to design,construction,and location.Appears to be operating <br /> properiy. <br /> � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br /> Iocated, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major <br /> upgreding of the system is required at this time. <br /> � 3 Does not meet current City standards in many respects relating to design,construction,or locatio�.Appears to be operating <br /> adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at <br /> this time. <br /> � 4 System may or may not meet current City standards for design,construction or location,but is faili�g to properly treat and <br /> dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site ptan <br /> must be submitted for review.Your contractor must obtain a permit before work is started. <br /> SYSTEM CONDITION (m Checked items may require your action) <br /> Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Dces not <br /> umpout not needed at this time. give accurate measurement of solids accumulation.) If tanks <br /> Solids accumulatio� in tanks indicates they should be pump- have not been pumped out within the last three years,they <br /> ed out this year to help prevent future problems. should be pumped out now. <br /> O Solids �cumulation in tanks is at a critical level. Tanks Drai field inspection indicates: <br /> should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident. <br /> ❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not critical yet. <br /> within 48 hours to eliminate surface discharge. ❑ Dreinfield is saturated and visibly discharging untreated <br /> ❑ Inspectio� risera missing—tanks could not be inspected, effluent to the surface, This condition may require replace- <br /> Inspection risero (4"dia. pipe)must be instslled in each tenk ment or additions to drainfield. Contact the City Inspector <br /> at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. <br /> the last three years,they should be pumped out now. ❑ Drainfield exte�t and condition unknown. <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (depends on soil types,water Futu e Expansion <br /> ❑ Soil table and system condition) �dequate <br /> ❑ High water table �ow ❑ Fair <br /> ❑ Lot size ❑Medium ❑Poor <br /> ❑ Lake,wetland,or stream ❑ High ❑ Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surface discharge. <br /> COMMENTS: � r ^ � a S D' I�I��OIS <br /> '� r' <br /> 7-�9/ <br /> Date of Inspection eptic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy <br /> of the system under current conditions based on the available information. <br /> This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.