2011-01107 - new septic
Orono
>
Property Files
>
Street Address
>
L
>
Longview Circle
>
2350 Longview Circle - 03-117-23-23-0005
>
Septic
>
2011-01107 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:34:51 PM
Creation date
6/14/2017 2:12:34 PM
Metadata
Fields
Template:
x Address Old
House Number
2350
Street Name
Longview
Street Type
Circle
Address
2350 Longview Cir
Document Type
Septic
PIN
0311723230005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
contact Troy Johnso�at <br /> �'°^ Mound Design ��$ep����m <br /> 11.7 #or questions or Comment6 <br /> Property Owner. Tom Ryan Oate: 7/21/2011 <br /> 5ite Address: 235Q Longview Circle, Orono,MN PID: 03-117-23 23 0005 <br /> Comments: <br /> instnxtions: � =req'd input � =inpt�t or default �=ca�ulated field `"' =instatler info <br /> t� �bedroom Type � Residential System <br /> y �GPD design ftow <br /> 3� No Garbage disposal or pumped to sept9c <br /> � "� 2250 Gallon septic tank(minimum) Tank options: none <br /> s� 1.2 GPD/ftz mound sand loading rate <br /> � 10 ft rockbed width 62.5 ft rockbed length <br /> "' 3.0 ft laterat spacing 3.0 ft perforation spacing (maximum of 3 for both) <br /> end teed manifotd connection <br /> s) *'"�(aterals 60.5 feei long 21.0 perfs/ laterat b3 perts total <br /> 1 a perf ineans the first perf starts at the middle feed manifoid) <br /> 9� "• 7/32 fnch perts at �feet residuaE head gives 0.56 gpm fiow rate per perforation <br /> for this perf size 8 spac'sng, Ft pipe size on line 12, max perfs/laterat= 30 , �1ne#8 rnusC be less--� OK <br /> �a� 4.0 doses per day (4 rninimum) <br /> i�) 188 gailons per dose (treatment votame) <br /> �Z� 2.pp inch diameter laterals(or smaller)will meet'Sx pipe valume" <br /> ""* 2.00 inch diameter laterals (or smatler)must be used to meet"4x pipe volume"requi�emerst <br /> 2.00 inch diameter laterals (or smatler)will meet"3x pipe voolume" <br /> �3� "'• 35 feet of 2.0 inch supply l'►ne leads to �6 galtons of drainback volume <br /> ("top feed"manifold to controt the drainback) <br /> ia� 194 gallons TOTA�Qump out votume(trea[ment+drainback) <br /> �s) 12 feet vertical lift from pump to dispersal area, teads to a: <br /> ie) ""` 36 GPM @ 19 feet of head, Pump requirement (note: >50gpm may require an extra 3-6'of head) <br /> t�� *** 9250 gal Dose tank(minimum) at 25.00 gpi <br /> leads to a <br /> is� •'• 7.8 inch swing on Demand float, or timed dosing of 5.4 min ON (canfirm pump rate with drawdovm <br /> (to deliver 66%of design flow) 9 hrs OFF test arsd adjust as necessary) <br /> �v� 12 inches from bottom of tank to"pump OFF"ftoat, and/or to cover pump <br /> o) ••' 20 inthes from bottom of tank to"pump ON"float, or 12 inches to"timer ON'float <br /> �� *•' 23 inches fran bottom of tank to'Hi Leve["f[oat (add 5-15 inches if Time Dosed) <br /> � 675 gallons reserve capacity (after High t�evel Alarm is attivated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.