ELAFc� HEATING & A/C INC. PROJECT: CUSTOM 2-STORY(JONES)
<br /> 9303 PLYMOUTH AVE N STE 104 CLIENT: KEITH WATERS & ASSOCIAT
<br /> GOLDEN VALLEY, MN 55427 DATE: 11-15-95
<br /> RES-�ENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER: RANDY
<br /> CLI=VT INFORMATION:
<br /> Np,iv!_ : KEITH WATERS & ASSOCIATES, INC.
<br /> ADD��SS : LONGVIEW CIRCLE
<br /> CIT�, STATE : ORONO, MINNESOTA
<br /> TOT?.� BUILDING LOADS :
<br /> --- - --- -----------------------------------------------------------------------
<br /> BLDC. LOAD AREA SEN. LAT. + SEN. = TOTAL
<br /> DESC�IPTIONS QUAN LOSS GAIN GAIN GAIN
<br /> ------------------------------------------------------------------------------
<br /> 4-� WIND. DBL PN&STM CLR GLS WD FR 1, 130 35, 451 0 32, 722 32 , 722
<br /> 9-G FRENCH DOOR DBL CLR GLS WOOD FR 60 2, 881 0 2, 640 2 , 640
<br /> 9-� FRENCH DOOR DBL LOW E WOOD FR 64 2, 014 0 1, 216 1, 216
<br /> 12-= WALL R-19 +1/2"ASPHLT BRD (R-1 . 3) 3 ; 976 20, 117 0 4, 068 4, 068
<br /> 13-- PART R-19 +l/2"ASPHLT BRD (R-1 . 3) 438 1, 109 0 241 241
<br /> 15-C WALL 2-5 'BLW GRD 8/12" BLK+R-11 55 258 0 0 0
<br /> 15-G WALL >5 'BELOW GRD 8" BLK+R-11 1, 119 4, 426 0 0 0
<br /> 10-G DOOR WOOD PANEL 37 2 , 281 0 461 461
<br /> 11-C DOOR METAL POLYSTYRENE CORE 18 778 0 157 157
<br /> 16-� CEILING R-44 INSULATION 2 , 112 4, 469 0 1, 895 1, 895
<br /> 20-� FLOOR/OPEN CRAWL CARPET + R-30 217 699 0 76 76
<br /> 21-A BASEMT FLOOR 2'OR> BELOW GRADE 1, 895 4, 184 0 0 0
<br /> ------------------------------------------------------------------------------
<br /> SUBTOTALS FOR STRUCTURE: 11, 121 78, 667 0 43, 476 43 , 476
<br /> PEO��E 12 0 2, 760 3 , 600 6, 360
<br /> APP�IANCES 0 0 300 1, 200 1, 500
<br /> DUC'��10RK 0 0 0 0 0
<br /> INF=�TrcATION W.CFM: 410 . 5 S .CFM: 307 . 8 0 41, 538 6, 908 5, 079 11, 987
<br /> VENiILATION W.CFM: 90 . 0 S .CFM: 90 . 0 0 9, 108 2, 020 1, 485 3 , 505
<br /> ------------------------------------------------------------------------------
<br /> SENSIBLE GAIN TOTAL 54, 840
<br /> TEM� . SWING MULTIPLIER X 1 . 00
<br /> BUI=�ING LOAD TOTALS 129, 312 11, 988 54, 840 66, 828
<br /> ------------------------------------------------------------------------------
<br /> SUPPLY CFM AT 20 DEG DT: 2,425 CFM PER SQUARE FOOT: 0 .438
<br /> SQUP�tE FT. OF ROOM AREA: 5, 534 SQUARE FOOT PER TON: 993 . 715
<br /> TOTP?, HEATING REQUIRED WITH OUTSIDE AIR: 129 .312 MBH
<br /> TOTPL COOLING REQUIRED WITH OUTSIDE AIR: 5 . 569 TONS
<br /> CALC�LP,TIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J.
<br /> ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY.
<br /> BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS.