Laserfiche WebLink
� °� <br /> o : o <br /> ��i�;:��- CITY of ORONU <br /> � �r��;,j�,-, �, <br /> i ' �,,► <br /> � Municipal Offices <br /> � k �.:tr','� � . <br /> ��t� I"�'� G <br /> Street Address: °ISa-a►49-�6o O Mailing Address: <br /> 't.� '`.`"�r,;;. 4 <br /> $'�Hp � 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: C�a�� L U^5�,�`� ��r C j C <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage trea.tment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMIT'Y (1-31: � <br /> lO "CODE SYSTEM"An ISTS which meets all thelocation,design and conswction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An LSTS which dces not meet all the location,design and cons�uction standards of the current Orono <br /> Municipal Code but dces meet the tkuee foot separation requirement or two foot requir�ement for systems installed 1996 or earlier,and <br /> which is not fiiling or an i�inent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may�ot�et all the location,d�.sign,or construction stanchrds of We ciurent Orono Municipal Code and wk►ich is failing for any <br /> reason;and any ISTS with less than Uuce feet of unsaturated soil or sand between the distribution device and the limiting soil characterisdcs. <br /> TANK CONDTTION(5-71: <br /> Tank inspection indicates: <br /> �Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �1�t-a'L, � <br /> Make sure seatietanks are aumaed throu¢h manhole and not through white insaection pipes. This allows for the proner <br /> cleanin¢. Keeu water softner and iron filter discharee out of sentic svstem to arolons life of drainfeld. Ask aumuer to test <br /> alarm float to verifv alarm is still working in vour 6ouse. The alarm warns owner that seataee is about to backua into basement <br /> 7 Inspection risers missing-tanks could not be inspected. inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DR.AINFIELD CONDITION 8-10 : � <br /> Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield.is saturated and visibly discharging untreated ef�luent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> CONIl��NTS: M o.t�J �.. Se P ��S �O�k 4 K — <br /> � 'Z-U —U°-'c � � <br /> Daie of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report dces <br /> not guarantae or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />