My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info including old septic design
Orono
>
Property Files
>
Street Address
>
L
>
Long Lake Boulevard
>
1600 Long Lake Boulevard - 26-118-23-33-0032
>
Septic
>
septic info including old septic design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:18:14 PM
Creation date
6/13/2017 1:18:38 PM
Metadata
Fields
Template:
x Address Old
House Number
1600
Street Name
Long Lake
Street Type
Boulevard
Address
1600 Long Lake Boulevard
Document Type
Septic
PIN
2611823330032
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO �O� <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(;E TREATl�1T <br /> r�`,, � IN3PECTION REPORT <br /> '�� G~ <br /> 9kESHa�'� <br /> Owner• � �1�i�J Address• rC�/ . <br /> Permit �'s: ��� Dates: 19h� Contractora: C�/l� �l��r <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is l�.an existing system [ ] new construction> <br /> SYSTEM CONFORMITY C1-3): <br /> 1 "CODE SYSTEM'�-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactority by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system ►rhich does not meet all the location, design, and construction standards of the <br /> current City Codes, but was instetled according to the code in effect at the time of installation, and which <br /> is operating setisfactorily by treating and disposing of the entire current sewage input without discherging <br /> any pollutants into grand or surface waters. <br /> 3 "NON-CONFORMING STSTEM"-A prohibited system; a system located within a designated 100-year floodplain; eny <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failin�for any reason; and anv svstem with less than 3 feet of unsaturated soil or sa <br /> � �een t e ts . tmitinfl soi� cnaractertstres. <br /> (The limitin� soil characteristic �(r'has or [ ] has not been identified at this time. If the limiting soil <br /> characteristic has not been identi�F�ed, this classification may be subject to revision.) <br /> TANK CONDITION (5-10) � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Solids eccunulation in tanks indicates they should be rxanced out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. tanks should be punped out as soon as possible. <br /> System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. <br /> �� Inspection risers missing-tanks could rwt be inspected. lnspection risers (4" dia. pipe) must be instatled in each <br /> tank at next punpout. If tanks have not been punped out within the last three years, they should be punped <br /> out now. <br /> � Inspection pipe is located directl over tank baffle (does not give accurate measurement of solids accumulation>. <br /> If tanks have not been pu�out within the last three years, they should be punped out now. <br /> DRAINf1ELD CONOITION (11-14): , <br /> D ' field inspection indicates: <br /> Drainfield is dry, no surfacing evident. <br /> Sane evidence of surfacing, not critical yet. <br /> Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repa irs� must_be_completed within 90_d��,, <br /> 14 Drainfield extent aria'L'�r�f' un nown. <br /> LIMITING SITE FACTORS (slooe,setbacks.etc.): <br /> POTENTIAL FOR SYSTEM PAILURE (decends on soils.water table.etc.): <br /> C NTS: <br /> _ _ 1!'� <br /> Date of Inspection e ic System Inspector �� <br /> lv sh �ja . <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely an op�nion of the adequacy of the system under current conditions based on the available <br /> informatton. <br /> This report must be kept on the premises with the system locstion and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />