ICBO Eval uation Service, i nc . <br /> Asubs�d�aryco�po�ar�onofrhe International Conference of Building Officials <br /> Report No.3421 P <br /> EVALUATION REPORT November, 1985 <br /> Filing Category:MISCELLANEOUS STRUCTURES <br /> PATIO COVER ENCLOSURE A summary of the plans and design loads is shown in Table No.I. <br /> PATIO CONCEPTS,INC. Identification: A decal or identifying tag shall be installed on each ' <br /> 3�1�i'EST BLUERIDGE AVENUE enclosure.The decal shall bear the name of the manufacturer,report num- <br /> ORAtiGE,CALIFORNIA 92665 ber,design live load,horizontal wind load and wind uplift force. <br /> I.Subject:Patio Cover Enclosure. IIt.Evidence Submitted;Calculations and plans have been submitted. <br /> II. Description:The patio cover enclosures are to enclose an attached Flndin S <br /> patio cover complying with Chapter 49 of the appendix ro the code. The g <br /> patio cover must be one currently recognized in an ICBO evaluation report IV.Findings:That the Patio Cover Enclosures comply with the 1982 <br /> to resist lateral wind forces applied to the structure assuming it is fully Uniform Building Code,pro"vided they are installed in accordance with <br /> enclosed.The patio cover for nonbearing systems,as shown in the plans, plans that are included with this report. <br /> must be designed to resist lateral wind and supporting vertical loads and be <br /> submitted to the local building official for approval. This report is subject to re-examination in two years. <br /> TABLE NO.I <br /> DE81ON LOADS(PsQ <br /> ENCLOSURE PHRMITTED� <br /> fioot Liw Moriz. Wlntl (Bu�d on MorizontN <br /> DRAWING 1�. a(Sirow) YVI� Uplltt Wlnd Gleul�tloru) <br /> 7.5 <br /> 1945 10 10 and May be paztially enclosed2 <br /> 10 <br /> 1946 10 10 10 Mansard attachment <br /> 1947 Parts Details for Drawing No. 1948 <br /> 10 10 10 May be partiatly enclosedz <br /> 1948 (20)&(30) 10 10 May be partially enclosed2 <br /> 20&30 15&20 18.75 May be fully enclosed <br /> SR-I <br /> 10 10 10 May be partially enclosed2 <br /> SR-2 <br /> �No enclosure herein listed shall be permitted to be used for cerport,garage,storage or habitable room. <br /> zPatio cover enclosures designed(or a]0-pound-per-square-toot horimntal wind load are required to have one long wall and one additional wall with <br /> openings equal to at least 65 percent of the area below a minimum of 6 fat 8 inches of each wall measurcd from the floor.The rcquired openings may <br /> be enclosed with insxt screening and/or readily rcmovable transparcnt or vanalucent plastic nd mwe than 0.125;nch in thickness. <br /> (Corncted ApN1,1986) / <br /> - Evaluution nports of ICBO Evaluation Service,Inc.,are issued solely to provide information to Class A members of ICBO,utiliiieg the code upon <br /> ( which�he report is based.Evaluation reports are not to be construed as representing aesthetics or any o�her attributes nol specifically addresstd no►as <br /> `-.i an endorsement or recommendation for use of the subject report. <br /> � This report is based upon independen/tests or other technica!dnta submitted by the applicanl.The/CBO Eva(uation Service,/nc.,technrcal stafjhas <br /> rei•iex•ed�he test resu/ts and/or olher data, but does no1 possess test faci/ities�o make an indeperrdenJ verificalion. There is no warranly by tCBO <br /> E�•aluation Servrce,Inc., express or implied,as to any "FindrnR"or other maner in Ihe reporJ or as to any produet covered by the reporl. Thrs <br /> disclaimer includes,but is nol limited�o,merchantabi[ity. <br /> Page 1 Of 1 <br />