Fields
Template:
x Address Old
House Number
300
Street Name
Big Island
Address
300 Big Island
Document Type
Septic
PIN
2311723320027
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' ���� <br /> OSTP Pump Tank LTNIVERSITY <br /> ""����'y°" Design Worksheet OF MINNESOTA �y� <br /> DETERMINE TANK CAPACI7Y AND DIWENSIONS Project ID: v 07.14.15 <br /> 1. A. Design F(ow (Desiqn Sum.1A): zZ5 GPD <br /> B. Min.required pump tank capacity: 1000 Gal C.Recommended pump tank capacity: 1000 Gal <br /> D. Pump tank description: Demand to Gravity <br /> MEASURED TANK CAPACITY(existing tanks): <br /> 2. A. Rectangle area=Length(L)X Width(W) <br /> W idth <br /> �ft X � ft = �ft� <br /> B. Cirde area=3.14r�(3.14 X radius X radius) <br /> 3.14 X �Z ft - �ftZ <br /> Length <br /> C, Calculate Gallons Per Inch. Multiply the area from 1.A or 1.6, by 7.5 to determine the gallons per foot <br /> the tank holds and divide by 12 to calculate the gallons per inch. <br /> � ft2 X 7.5 gal/ft' =12 in/ft = �Gallons per inch <br /> Radiu <br /> D. Calculate Tota!Tank Volume <br /> Depth from bottom of inlet pipe to tank bottom: �in <br /> Total Tank Volume =Depth from bottom oJ inlet pipe (Line 4.A)X Gallons/Inch (Line 2) <br /> � in X �Gallons Per Inch= �Gallons <br /> MANUFACTURER'S SPECIFIED TANK CAPACITY(when available): <br /> 3. A. Tank Manufacturer: Infiltrator Note:Design colculotions are bosed on <br /> this specific tank.Substftuting a <br /> B. Tank Model: IM-1060 different tonk mode(will change the <br /> C. Capacity from manufacturer: 1094 Gallons Pump Jloat or timer set[ings.Contact <br /> designer if changes are necessary. <br /> D. Gallons per inch from manufacturer: 24.9 Gallons per inch <br /> E. Liquid depth of tank from manufacturer: 44.0 inches <br /> DETERMINE DOSING VOLUME <br /> 4• Calculate Volume[o Cover Pump (The inlet of the pump must be at least 4-inches from the bottom of the pump <br /> tank @ 2 inches of water covering the pump is recommended) <br /> (Pump and block height+2 inches)X Gallons Per Inch (2C or 3E) <br /> ( 14 jn + 2 inches) X 24.9 Gallons Per Inch = 398 Gallons <br /> 5. Minimum De(ivered Volume = 4 X Volume of Distribution Piping: <br /> -Line 17 oj the Pressure Distribution or Line 11 oj Non-leve! �Gallons(minimum dose) <br /> 6. Calculate Moximum Pumpout Volume (25%of Design Flow) <br /> Design Flow: 225 GPD X 0.25 = 56 Gallons(maximum dose) <br /> 7. Selec[a pumpout volume that meets both Mfnimum and Moximum: 56 Gallons <br /> 8. Calwlate Doses Per Day =Design Flow=Delivered Volume VQ�UIYI�'O��.�RR'�llid��t. <br /> 225 gpd= 56 gdl = ��� .�jp@ <br /> 9. Calculate Drainback: <br /> A. Diameter of 5upply Pipe= �2 inches �� , �.�i,l!'�i� <br /> D131y1Q�t' �?'F44� <br /> B. Length of Supply Pipe= 26 feet <br /> {i�cl�es� {+Catbrr�) <br /> C. Volume of Liquid Per Lineal Foot oJ Pipe = 0.170 Gallons/ft 1 0.045 <br /> D. Droinback =Length of Supply Pipe X Volume of Liquid Per Lineal Foot of Pipe �.25 �.�7$ <br /> 2e ft x o.»o gal/ft = a.a Gallons 1.5 0.110 <br /> 10. Totol Dosing Volume =Dellvered Volume plus Drainback 2 �.�70 <br /> 56 gal+ a.a ga�= bo Gallons 3 0.380 <br /> 1 i. Minimum Alarm Volume=Depth of alarm(2 or 3 inches)X gallons per inch of tank <br /> ��n X 24.9 gal/in = 49.8 Gallons 4 0.661 <br />