<br /> ' Rfiv�ac-Resiaeritlal�&.I.IghbComri�efclal'FN�I.IC'L.dads . .Elite'•Software��ev�lo`�iner�,inc..
<br /> � Rfccar He�#ng and CoolfnQ �
<br /> And r �St SSL�4 Wooddale Ho�sn�At�gh�Unit
<br /> .2
<br /> Total Buildin Summa Loads
<br /> � po�eri n t Sen Tota
<br /> � 'os •� � � � i�
<br /> 4A-6-d: Glazing-Douhle pane law-e(e=0.20 or less), 118.4 3,321 p Z,54p Z�5qp
<br /> high performance,sliding glass door,e=Q,p5 on
<br /> surtace 2,any frame,outdoor insect screen with 5096
<br /> coverage, u-value 0.33,SHGC 0.33
<br /> Andeisen:Giazin�-Gperable window,wood sash,u-value Z95.9 7,295 0 5,818 5,819
<br /> a.za, sH�c o.a2
<br /> Andersen:Glazing-operable window,wood sash,outdoor 80.5 1,984 0 2,438 2,438
<br /> insect screen w�th 50%coverage, u-value 0.29,
<br /> SHGC 0.32
<br /> 17 N: Door-Metal-Polystyrene Cor� 44.4 1,321 0 373 373
<br /> 12F-0sw:Wall-Fr�me, R-21 insulation in 2 x 6 stud 2239.3 12,373 0 1,937 1,837
<br /> cavit�r,no board insulation, siding fini9h,wood studs
<br /> 1580-70sf-4:Wail-8asemant, , R-10 board Insulation to 464.5 755 0 0 0
<br /> floor,no interior flnish,4'floor depth
<br /> 15B0-10sf-8:Wei�Basement, , R-10 board insulation to 399 9,964 p 7g 7�r
<br /> floor, no interior finish,8'floor depth
<br /> 168-50: Roof/Ceiling-UncferAtticwith Insulation on Attic 1748 2,988 0 1,676 �,g�g
<br /> Floor(also use for Knee Walls and Partition
<br /> Ceilings).Vented Attic, No Radiant Barrier, Dark
<br /> Asphalt Shinglas or Dark Metal,Tar and Gravel or
<br /> Membr�ne, R-50 insulation
<br /> 21A-32: Fioor-Basement, Concr�te slab,any thickness, 2 1728 2,938 p p Q
<br /> or more feet below grade, no insulation below floor,
<br /> any floor cover, shor6est side of flocr slab is 32'wide
<br /> 20P-30: Floor-Over open crawl space or garage, Passive, �18 5�{ Q 5 5
<br /> R-30 blanket insulation,any cover
<br /> Subtotals for structure: a.34,973 0 14,984 14,g64
<br /> People_ 5 � 1,000 1.150 2,150
<br /> Equipment: 722 7,070 7,792
<br /> Lightin�: Q Q �
<br /> Ductwork: 0 0 0 0
<br /> (nfiltration:Winter CFM:49.Summer C�M:24 4,401 376 336 712
<br /> Vent}letlon:Winter CFM: 130, Summer CFM: 130 4,7i7 2,017 721 2,738
<br /> Exhaust:Winter CFM: 130, Summer CFM: 130
<br /> Humid�cation�nter)8.20 gaUday: 3,006 p 0 0
<br /> AED Excursion: _�, 0 0 3,235 3,235
<br /> Total Building Load Totals: 47,097 4,115 27,476 31,591
<br /> :��k�( :
<br /> Total�uilding Supply CFM: 1,253 CFM Per quare ft.: 0.361
<br /> Square ft.of Room Area: 3,474
<br /> Voiume tft'): 28,104
<br /> Total Heating Required Including Ven�laGon Air. 47,097 Btuh 47.097 H
<br /> Total Sensible Gain: 27,�76 Btuh 87 96
<br /> Total Latent Galn: 4,115 Btuh 13 4i
<br /> Total Cooling Required lncluding Ventila#ion Air. 31,591 �tuh
<br /> �
<br /> Rhvao is an ACCA approved Manual J and Manual D camputer program.
<br /> Calculations are pertormed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
<br /> All camputed results are estimates as building use and weather may vary.
<br /> 8e sur+e to select a unit that meets both sensibla and latent loads according to the menufactu�e�'s porformance data at
<br /> your design conditions.
<br /> C:1...IWoaddale hlogan 799 Brid�water.rh9 Monday,Apri110,2017,9:27 AM