Laserfiche WebLink
OSi19i2010 16:31 '�. 95:445?867 9000L [�003 <br /> 1.0 �as and Electrical raauirements: <br /> 1,1 Input Voltage: 120 Vac/60 Hz to Grand Effects Control Danel <br /> 1.2 Output Voltage: 24 Vac <br /> 1.3 Gas type: Natural Gas Fropane <br /> 1.4 Gas Pressure: Nominal: 7"wc 11"wc <br /> 1.5 Water Flow: 10-12 gpm <br /> 1.6 Gas flow: 1 Bowl system: 60,000-80,000 btu!hr <br /> 2 Bowl system: 120,000-160,000 btu/hr <br /> 3 Bawl system: 180,000-240,000 btu/F�r <br /> 4 Bow1 system: 240,000-320,000 btu/hr <br /> Note: Check with your gas supplier to verify gas flows and pr�ssures available at the Iocation <br /> of your installation. In many cases utility companies will instal! larger meters at no charge to <br /> accommodate larger fiows. <br /> 2.0 InstailatJon <br /> Warning: l'his unit la for outdoor use only <br /> Rscummended CSAIAGA Clearances: Sides 4 ftlTcp 6it <br /> 2.1 Do not install near any combusfibles such as wood structures, fuels, ciothing, fabrics <br /> ot dry vegetation. <br /> 2,2 instal{ Bawis weil out of the way of pedestrian traffic, <br /> 2.3 installation shall be performed by a licensed contractor. Ali aspects of installstion <br /> must conform to locai or nationa! codes, or in the absence of codes, with Natural Fuef <br /> Gas Code ANZI Z223.1. <br /> The Control Panel and approved gas valve shail be located where they can be easily <br /> accessible so tt�at the gas can be shut off qufckly in case of an emergency. <br /> 2.4 lnstall the Control Panel and gas piping as shown in Fig. 1(Natural Gas) or Fig. 2 <br /> {Propane Gas) or Fig.3 (Cammercial Installation). <br /> 2.5 Note that propane piping is different than natural gas (shown in Fig. 1 and Fig.2). <br /> 2.6 The gas piping shaN be installed underground beriveen the Control Panel and each <br /> Flrs Bowl as showm in Fig. 1. The piping shall be reduced to 1/2° NPT or�arger at <br /> each bowl as shown in Fig. 4. <br /> 2.7 Low voltage wiring (14 or 16 ga. 24Vac) shall be installed undemround between the <br /> Cont�ol Panel and each Bawl. Wire per Grand EfFects wiring diagram. 120 v source <br /> into Cantrol Panel can come from any 120v source, induding pool controller or home <br /> system. <br /> 2.8 Maintain good piping practice by keeping pipe length and elbows to a minimum to <br /> eliminate unnecessary pressure drops. Corrugated flex gas lines should not be used. <br /> 2.81 Gas and eiectric shouid be centered in mlddle of column, <br /> 2.85 Dr commeraal installations, it is recommended to instafl a keyed switch and kill switch <br /> located in close proximity and in vislble sight of feature or features. The keyed and kill <br /> switches are supplied by others. <br /> � <br /> � <br />