My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info - old address
Orono
>
Property Files
>
Street Address
>
L
>
Little Orchard Way
>
2850 Little Orchard Way - 09-117-23-21-0007
>
Septic
>
septic info - old address
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:49:12 PM
Creation date
5/8/2017 2:05:24 PM
Metadata
Fields
Template:
x Address Old
House Number
2850
Street Name
Little Orchard
Street Type
Way
Address
2850 Little Orchard Way
Document Type
Septic
PIN
0911723210007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO �O� <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON–SITE SEWA(iE TREATl�:NT <br /> � �, INSPECTION REPORT <br /> ti <br /> ��9k'ESH.��'�G <br /> Owner• �� v�. `OrL��� Address• '" , � <br /> � <br /> Permit �'s: � ates:__/��e1� Contractors: Sl!/��l-� <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is [ ] an existing system [ ] new construction> <br /> STSTEM CONFORM[TY (1-3): <br /> 1 "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface uaters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface uaters. <br /> "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any s stem with less than 3 feet of unsaturated soil or sand <br /> --� between the distribution device and the limiting <br /> � S� cor.► r�Qy� w/�1�,o e yarY, <br /> (The limiting soil characteristic� has or [ ] has not been identified at this ime. If the limiting soil <br /> characteristic has not been identi ied, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be punped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. Tanks should be punped out as soon as possible. <br /> 8 System is discharging to the surface. 7anks must be pumped out within 48 hours to eliminate surface dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed tn each <br /> tank at next pianpout. If tanks have not been punped out within the last three years, they should be punped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> [f tanks have not been punped out within the last three years, they should be punped out now. <br /> DRAINFIEID CONDITION (11-14): <br /> Dr field inspection indicates: <br /> �Drainfield is dry, no surfacing evident. <br /> �rz Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent arxi condition unknown. <br /> LIMITING SITE FACTORS (slope,setbacks.etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table,etc.): � — <br /> MMEN S: � � ' <br /> i Jr!^ � <br /> � <br /> a � f - ��� <br /> D te of Inspection Sep ic System Inspector �S g.Cy h��qy�r��►2 <br /> ry� �eS/��/�P� InvSt' <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage ot er transfer of �i�,� <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely an opinion of the adequacy of the system under current conditions based on the available�'�� <br /> informat�on. ��� <br /> This report must be kept on the premises with the system locetion and punping records. ' <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.