CITY OF ORONO �O� <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON–SITE SEWA(iE TREATl�:NT <br /> � �, INSPECTION REPORT <br /> ti <br /> ��9k'ESH.��'�G <br /> Owner• �� v�. `OrL��� Address• '" , � <br /> � <br /> Permit �'s: � ates:__/��e1� Contractors: Sl!/��l-� <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is [ ] an existing system [ ] new construction> <br /> STSTEM CONFORM[TY (1-3): <br /> 1 "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface uaters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface uaters. <br /> "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any s stem with less than 3 feet of unsaturated soil or sand <br /> --� between the distribution device and the limiting <br /> � S� cor.► r�Qy� w/�1�,o e yarY, <br /> (The limiting soil characteristic� has or [ ] has not been identified at this ime. If the limiting soil <br /> characteristic has not been identi ied, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be punped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. Tanks should be punped out as soon as possible. <br /> 8 System is discharging to the surface. 7anks must be pumped out within 48 hours to eliminate surface dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed tn each <br /> tank at next pianpout. If tanks have not been punped out within the last three years, they should be punped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> [f tanks have not been punped out within the last three years, they should be punped out now. <br /> DRAINFIEID CONDITION (11-14): <br /> Dr field inspection indicates: <br /> �Drainfield is dry, no surfacing evident. <br /> �rz Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent arxi condition unknown. <br /> LIMITING SITE FACTORS (slope,setbacks.etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table,etc.): � — <br /> MMEN S: � � ' <br /> i Jr!^ � <br /> � <br /> a � f - ��� <br /> D te of Inspection Sep ic System Inspector �S g.Cy h��qy�r��►2 <br /> ry� �eS/��/�P� InvSt' <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage ot er transfer of �i�,� <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely an opinion of the adequacy of the system under current conditions based on the available�'�� <br /> informat�on. ��� <br /> This report must be kept on the premises with the system locetion and punping records. ' <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />