Laserfiche WebLink
Rtwac Residentiait8 Light C.ommerciai FIVAC Loads Elite Software Development�Inc. <br /> Wccar Heat�ng and Cijoltii9 '� Woodd,a'le Stonetiay Left:Er�d Unit <br /> • Aridov.er•MN=55304 <br /> .`Pa e"1 <br /> Pro'ect Re ort <br /> tGeQeiak=P ecf=1'nfoririat�on .,��k,�;���� � 3� � ; r� ��..�.�-� .y���� � , �a: � � f ,.� ��, {,�° `��: i <br /> --- - r� <br /> Project Title: Wooddale Stonebay Left End Unit <br /> Designed By: Aaron <br /> Project Date: 2/3/17 <br /> Project Comment: <br /> Client Name: Wooddale Builders <br /> Company Name: Riccar Heating And Air <br /> Company Representative: Aaron <br /> Company Address: 2387 Station Parkway NW <br /> Company City: Andover, MN 55304 <br /> Company Phone: 763-754-4000 <br /> Company Fax: 763-754-0132 <br /> Company E-Mail Address: Aaron@riccarhvac.com <br /> Company Website: riccarhvac.com <br /> :�e.�f� n�aLC1.,x,r �.�.`a - A_ :.�.ie2�h4 :t"�:c�.iS�>`wPr-%t't�:'�F.�,.,.�',�._�..w��, t i:��� otf.-�i � z < ]::�` �6i:�r�� <br /> Reference City: Minneapolis/St. Paul AP, Minnesota <br /> Building Orientation: Front door faces East <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> Drv Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference <br /> Winter: . -15 -11.42 n/a 30% 70 25.53 <br /> Summer: 88 71 44% 50% 75 24 <br /> C .:S,Ci �x '_urGJa �f c 1 t � �`�W� -tk, �1 �a�} f�! y ; 7- � =�ip s� rt� <br /> s,' z. �. �+.,�' _•��� ��.r#�^:�.���< m�f.# a+ ,.�s ' uv .;_rF.,.�,��� <br /> Total Building Supply CFM: 1,269 * }�.CFM Per Square ft.: . 0.366 �� <br /> Square ft. of Room Area: 3,468 Square ft. Per Ton: 1,312 <br /> Volume (ft�: 29,812 <br /> � �,u�l,dm Loa�ds r��, � _ x:�x� �x�_.��`.��z��x�r���, _� > �� ',. ` �.t f <br /> t�s' �, <br /> Total Heating Required Including Ventilation Air: 46,146 Btuh 46.146 MBH <br /> Total Sensible Gain: 27,813 Btuh 88 % <br /> Total Latent Gain: 3,908 Btuh 12 °lo <br /> Total Cooling Required Including Ventilation Air: 31,721 Btuh 2.64 Tons(Based On Sensible+ <br /> Latent) <br /> N�.te�J,'��,.Lt as;� .,r., .4.��'d,.�f.�,. a, 'C e1. `�i,f= � � �'� ��*�'Sf' ��� b �t <br /> Rhvac is an ACCA approved Manual J and Manual�� � ��� ���� � .��� . � � ��� � � �� _� f �� �� � �_„�"�;� � <br /> ' D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data <br /> at your design conditions. <br /> C:\...\Wooddale left end Stonebay.rh9 Friday, February 03,2017, 3:46 PM <br />