My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-00299 (Septic)
Orono
>
Property Files
>
Street Address
>
A
>
Augusta Street
>
4705 Augusta Street - 06-117-23-32-0006
>
Septic
>
2017-00299 (Septic)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:26:39 PM
Creation date
4/27/2017 8:52:53 AM
Metadata
Fields
Template:
x Address Old
House Number
4705
Street Name
Augusta
Street Type
Street
Address
4705 Augusta St
Document Type
Septic
PIN
0611723320006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011purplecode Mound Design <br /> www SepticResource com (vers 15 2) <br /> Property Owner: Norton Homes Date: 1/23/2017 <br /> Site Address: 4705 Augusta Street PID: 0611723320006 <br /> Comments: <br /> instructions: � = enter data �� = adjust if desired � = computer calculated - DO NOT CHANGE! <br /> �� �5 bedroom Type C� Residentiat System <br /> . 750 GPD design flow <br /> Yes Garbage disposat or pumped to septic SQ% targer tank with multipte comp/tanks <br /> a 2250 Gat Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br /> Tank options: none <br /> -, 1•2 GPD/ftZ mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. tong rockbed <br /> �.� 10.0 ft rockbed width 62.5 ft rockbed length <br /> �� 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both� <br /> end feed manifold connection <br /> �� �laterals 60.5 feet long 21.0 perfs / lateral 63 perfs totat <br /> 11/2 a perf ineans the first perf starts at the middle feed manifold) <br /> ��, 7/32 inch perfs at �1 feet residual head gives 0.56 gpm flow rate per perforation <br /> for this perf size tx spacing, t� pipe size on tine 12, max perfs/taterat = 30 . tine #8 must be less --> <br /> ;a, 4.0 doses per day (4 minimumj <br /> i i� 188 gatlons per dose (treatment votume) <br /> 2.00 5x <br /> �'� 2.� inch diameter taterals must be used to meet"4x pipe volume"requirement <br /> 2.00 3x <br /> �� 38 feet of 2.0 inch suppty tine teads to �gaUons of drainback volume <br /> (Tip: "top feed" manifold to control the drainback� <br /> i-�, 194 gattons TOTAL pump out volume (treatment + drainbacki <br /> i�� 9 feet vertical lift from pump to mound laterals, teads to a: <br /> ir„ 36 GPM� 16 feet of head, Pump requirement �note: >50gpm may require an extra 3-6'of head) <br /> i,: 750 gal Dose tank (code minimum) 1300 gal Dose tank �design size ! LUG req'd1 at 25.49 gpi <br /> leads to a <br /> ;r 7.6 inch swing on Demand float, or timed dosing of 5.4 min ON �confirm pump rate with drawdown <br /> ([his delivers Average flow, =70`�,of Peak design flow)�9 hrs OFF test and adjust as necessary) <br /> ���, 12 inches from bottom of tank to"Pump OFF"ftoat <br /> �� � 20 inches from bottom of tank to"Pump ON"ftoat, or 12 inches to'Timer ON"float if time dosed <br /> =i� 23 inches from bottom of tank to"Hi Level'"ftoat, or 33 inches to"Hi LeveC'float if time dosed <br /> __, 714 gattons reserve capacity (after High level Atarm is activatedi <br />
The URL can be used to link to this page
Your browser does not support the video tag.