Laserfiche WebLink
CITY OF ORONO �O� <br /> Municipal Otfices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON—SITE SEWA�iS TREA'1'l�I�IT <br /> INSPECTION REPORT <br /> ti <br /> ti <br /> ��`�$ 04'�G <br /> Es8 <br /> � <br /> Owner• Address: � <br /> q�9-�g '� <br /> Permit �'s: Date :� ��Contractors: . <br /> City ordinance number 100 re�ires that each on-site sewage treatment system in Orono be inspected on a regular besis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is ,(� an existing system [ ] new construction) <br /> SYSTEM CONFORMITY (1-3): <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, end which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutents into ground or surface Waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction starxiards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-C�IFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standerds of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of imsaturated soil or sand <br /> between the distribution device and the limiting . m <br /> (The limiting soil characteristic �has or [ ] has not been identified t t is fi� I�t b�lim�ing s6il <br /> characteristic has not been identi i , this classification may be subject to revision.) <br /> TANK C�IDITION (5-10): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> b Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br /> 7 Solids acumulation in tanks is at a critical level. Tanks should be punped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. lnspection risers (4�� dia. pipe) must be installed tn each <br /> tank at next punpout. If tanks have not been punped out within the last three years, they should be punped <br /> out now. <br /> 10 Inspection pipe is located directl over tank baffle (does not give accurate measurertient of solids accumulation). <br /> ert e <br /> !f tanks have not been out within the lest three�[ears ey should out now. <br /> DRAINFIELD CONDITION C11-14): <br /> D�nfield inspection indicates: <br /> t Drainfield is dry, no surfacing evident. <br /> Sane evidence of surfacing, not critical yet. <br /> 13 Drainfietd is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repeirs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (sloae,setbecks,etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (decends on soils.water table.etc.): <br /> / <br /> O ENTS: <br /> S <br /> Date of Inspection p c Sya ns ctor <br /> Note: In the event that this inspection report is used tp satisfy the rec�irements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to f�mction <br /> properly� but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> informat�on. <br /> This report must be kept on the premises with the system loc�tion and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />