Laserfiche WebLink
RHVAC-Residential 8 Light Commercial HVAC Loads Program � Elite Software Development,Inc. <br /> Ditter,Inc. Jones <br /> Hamel,MN 55340-9691 11N 1/OS Page 2 <br /> • �PYoject Summary <br /> Project: Jones Company: Ditter Cooling and Heating <br /> Client: Celayne Jones Representative: Doug Bjork <br /> Address: Address: 820 Tower Drive <br /> City: Long Lake, Mn City: Medina, MN. 55340 <br /> Phone: Phone: (763)-478-8558 <br /> Fax: Fax: (763)-478-2426 <br /> Comment: <br /> Design Data <br /> Project Name: Jones <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 Feet <br /> Elevation Sensible Adj. Factor: 1.000 <br /> Elevation Total Adj. Factor: 1.000 <br /> Outdoor Outdoor Indoor Indoor Grains <br /> Drv Bulb Wet Bulb Rel.Hum. Drv Bulb Difference <br /> Winter: -20 N/A N/A 72 N/A <br /> Summer: 95 75 50% 72 42 <br /> Check Figures <br /> Total Building Supply CFM: 1000 CFM per square foot: 0.251 <br /> Square feet of room area: 3,978 Square feet per ton: 1,143.324 <br /> Building Loads <br /> Total heating required with outside air: 69,065 Btuh 69.065 MBH <br /> Total sensible gain: 32,149 Btuh 88 % <br /> Total latent gain: 4,265 Btuh 12 % <br /> Total cooling required with outside air: 36,414 Btuh 3.034 Tons(based on sensible+ latent) <br /> 3.479 Tons(based on 77%sensible capacity) <br /> Notes <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> Monday,November 10,2008 <br />