Laserfiche WebLink
RHVAC-Residential&Light Commercial HVAC Loads Program � Elite Software Development,Inc. <br /> Ditter,Inc. Jones <br /> Hamel,MN 55340-9691 11l11/08 Page 5 <br /> • System#1 Zone#1 Summary Loads <br /> Component Area Sen. Lat. Sen. Total <br /> Description Quan Loss Gain Gain Gain <br /> 3E Window Double Pane Low Emit TIM Frame 419 15,380 0 14,227 14,227 <br /> 8M Glass Door pouble Clear Glass Wood Frame 78 3,953 0 3,635 3,635 <br /> 12D Wall R-11 + 1/2"Asphlt Board(R-1.3) 1,990 14,647 0 4,234 4,234 <br /> 12H Wall R-19+ 1/2" Gypsum Board(R-0.5) 1,613 8,904 0 2,573 2,573 <br /> 161 Ceiling R-44 Insulation 1,989 4,209 0 2,150 2,150 <br /> 21A Basemt Floor 2'or More Below Grade 1,989 4,392 0 0 0 <br /> Subtotals for structure: 8,078 51,485 0 26,819 26,819 <br /> Active People: 4 0 920 1,200 2,120 <br /> Inactive People: 0 0 0 0 0 <br /> Appliances: 0 0 0 1,200 1,200 <br /> Lighting: 0 0 0 <br /> Ducfinrork: 0 0 0 0 0 <br /> Infiltration:Winter CFM: 179.1, Summer CFM: 119.4 497 17,580 3,345 2,930 6,275 <br /> ' Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 n/a n/a n/a n/a <br /> Sensible Gain Total: 32,149 <br /> Temperature Swing Multiplier: X1.00 <br /> Zone Load Totals: 69,065 4,265 32,149 36,414 <br /> Check Figures <br /> Supply CFM: 1,000 CFM per square foot: 0.251 <br /> Square feet of room area: 3,978 Square feet per ton: 1,143.324 <br /> Zone Loads <br /> Total heating required with outside air: 69,065 Btuh 69.065 MBH <br /> Total sensible gain: 32,149 Btuh 88 % <br /> Total latent gain: 4,265 Btuh 12 % <br /> Total cooling required with outside air: 36,414 Btuh 3.034 Tons(based on sensible+ latent) <br /> 3.479 Tons(based on 77% sensible capacity) <br /> Monday,November 10,2008 <br />