My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Terrace
>
1840 Lakeview Terrace - 27-118-23-42-0010
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:22:07 PM
Creation date
4/25/2017 1:05:36 PM
Metadata
Fields
Template:
x Address Old
House Number
1840
Street Name
Lakeview
Street Type
Terrace
Address
1840 Lakeview Terrace
Document Type
Septic
PIN
2711823420010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> On the North Shore of <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT � POST OFFICE BOX 66 <br /> 1335 S. Brown Rd. <br /> � � � � Crystal Bay,MN 55323 <br /> 473-7357 <br /> OWNER [J� 1.1�6fY� AODRESS !U �O GG1,�Evr�J /�C✓✓/a'Cf <br /> PERMIT NO.'S. x �-1 DATES IL'��6� CONTRACTORS S✓����� <br /> City Ordina�ce No.210 requires Mat each onsite sewage treatment syatem in Oro�o be inapected on a regular basis.The onsite sewage <br /> ueatment system at the above address has been i�apected and appears to fall into the category checked below. <br /> (This is � an existing system ❑ new construction) <br /> � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating <br /> properly. <br /> � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br /> located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major <br /> upgrading of the system is required at this time. <br /> � 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating <br /> adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at <br /> this time. <br /> � 4 System may or may not meet current City standards for design,construction or location,but is failing to properly treat and <br /> dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City tnspector to discuss system repair/ <br /> replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a permit before work is started. <br /> SYSTEM CONDITION (m Checked items may require your action) <br /> Ta�k'nspection indicates: ❑ Inspection pipe is loceted directly over tank baffle.(Does not <br /> �Pumpout not needed at this time, give accurate measurement of solids accumulation.) If tanks <br /> � Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three y�rs,they <br /> ed out this yeer to help prevent future problems. should be pumped out now. <br /> ❑ Soli� accumulation in tanks is at a critical level. Tanks Drainfistd inapection indicetes: <br /> should be pumped out as soon as possible. � Drainfield is dry,no surfacing evident. <br /> ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. <br /> within 48 hours to elimi�ate surface discharge. O Drainfield is seturated and visibly discharging u�treated <br /> ❑ Inspection risera missi�g—tanks could not be inspected, effluent to the surface. This condition may require replace- <br /> Inspection risera (4"dia. pipe)must be instelled in each tank ment or additions to drainfield, Contact the City Inspector <br /> at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90�ys. <br /> the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Potential for System Failure Site Capabitities for <br /> ❑ Slope (depends on soil types,water Future Expansion <br /> ❑ Soil table and system condition) ❑ Adequate <br /> � High water table � Low �Fair <br /> ❑ Lot size Medium ❑Poor <br /> ❑ Lake,wetla�d,or stream ❑ High O Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surface discha�ge. <br /> COMMENTS: <br /> /�-g 90 <br /> Date of Inspection eptic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy <br /> of the system under current conditions based on the available information. <br /> This report must be kept on the premises with system locatio�and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.