My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Terrace
>
1830 Lakeview Terrace - 27-118-23-42-0011
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:22:09 PM
Creation date
4/25/2017 12:47:45 PM
Metadata
Fields
Template:
x Address Old
House Number
1830
Street Name
Lakeview
Street Type
Terrace
Address
1830 Lakeview Terrace
Document Type
Septic
PIN
2711823420011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
View images
View plain text
CITY OF ORONO � O� <br /> Municipel Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(iE TRI;A'1'l�NT <br /> r�, �, INSPECTION REPORT <br /> � G� <br /> �9kESH.�4'� <br /> � ?7a i' <br /> Owner: Address: �J <br /> Permit #'s: Dates: �-a9 9� Contractora: 1 r <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is (�an existing system [ ] new construction> <br /> STSTEM CONFORMITY 1-3 : <br /> "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any potlutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-C�IFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any,system with less than 3 feet of w�saturated soil or sand <br /> between the distribution device and the limiting so�l characteristics. <br /> (The limitin� soil characteristic "[�.has or [ 7 has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): <br /> Tp�1t inspection indicates: <br /> (5/ Punpout not needed at this time. <br /> `6 Solids accunulation in tanks indicates they should be putiped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. 'fanks should be punped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pu�ed out within 48 hours to eliminate surface dischar�e. <br /> 9 [nspection risers missing-tanks could not be inspected. Inspection risers (4" dia, pipe) must be installed in each <br /> tank at next p�mpout. If tanks have not been pumped out within the last three years, they should be punped <br /> OUL r10M. <br /> 10 Inspection pipe is lxated directl over tank baffle (does not give accurate measurement of solids accunulation). <br /> 1f tanks have not been p��out within the last three years, they should be ptmped out now. <br /> DRAINFIELD CONDITION C11-14): <br /> D�field inspection indicates: <br /> 1 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfecing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS Csloce.setbecks.etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (deaends on soils.water table,etc.): <br /> COMMENTS: <br /> Date of inspection tic System Znspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certity that an existing system will continue to function <br /> properly� but is merely an opim on of the adequacy of the system under current conditions based on the available <br /> informatton. <br /> This report must be kept on the premises With the system location and pumping records. <br /> WHITE COPYllnspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).