My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Terrace
>
1803 Lakeview Terrace - 27-118-23-43-0003
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:22:26 PM
Creation date
4/25/2017 11:47:04 AM
Metadata
Fields
Template:
x Address Old
House Number
1803
Street Name
Lakeview
Street Type
Terrace
Address
1803 Lakeview Terrace
Document Type
Septic
PIN
2711823430003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO � O� <br /> Municipal Offices O O <br /> Post Office eox 66 <br /> Crystal eay, MN 55323-0066 � � ON-SITF SEWA(;E TREATl�ENT <br /> r�, �, INSPECTION REPORT <br /> '�� G~ <br /> '� <br /> 9kEsHo4`' <br /> Owner:= 1���. V�l Y/�ir� Address: �1C�� L!�'KP/j/'�d��`1/(��i <br /> Permit �'s: Dates: �D'c�� �Contractora: ,1�7Y� ��V/11�.T�lPI'�- <br /> City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (7his is ,�.an existing system [ ] new construction) <br /> SYSTEM CO�IFORMITT C1-3): <br /> t "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any poltutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into gro�d or surface waters. <br /> "NON-CONFORMING SYSTEM��-A pr�ibited system; a system located within a designated 100-year ftoo�tain; any <br /> system which mey or mey not meet all the location, design, and construction standards of the current City <br /> Codes and which is faiting for any reason; and an s stem with tess than 3 feet of unsaturated soil or sand <br /> �between the distribution device and the limiti c a ac . /�. <br /> (The limitin� soil characteristic as or [ ] has not been identified a is �me. f e imiti g soil <br /> characteristic has not been identi ied, this classification may be subject to revision.) <br /> TANK CONDIT(ON (5-10): n� J_ <br /> Tank inspection indicat . `�L re <br /> 5 Pumpout not at this time. <br /> � Solids a lation in tanks indicates they should be pumped out this year to help prevent future problems. <br /> �neietien�in tanks is at a critical level. Tanks should be punped out as soon as possible. <br /> ystem is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. lnspection risers (4" dia. pipe) must be instelled in each <br /> tank at next pumpout. 1f tanks have not been punped out within the last three years, they should be p�mped <br /> out now. <br /> 10 Inspection pipe is loceted directly over tenk beffle (does not give accurate measurement of solids accunulation). <br /> If tanks have not been punped out within the last three years, they should be punped out now. <br /> DRAINPIELD CONDITION C11-14): ,`� <br /> a� field inspection ind' r-��d�'spi� vy <br /> Drainfield is rlry, sur cing eviden <br /> 12 Some evidence of su , e!-e al yet. <br /> 13 Drainfield is seturated and visibly discharging �mtreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITiNG SITE FACTORS (slope,setbacks,etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (deoends on soils.water table.etc.): <br /> O NTS. � <br /> � � <br /> Date of nspection p 'c System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely an opim on of the adequacy of the system under current conditions based on the available <br /> informetion. <br /> This report must be kept on the premises with the system locetion and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.