My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-01328 - septic
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
795 Lakeview Parkway - 06-117-23-43-0014
>
Septic
>
2015-01328 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:29:00 PM
Creation date
4/24/2017 3:02:09 PM
Metadata
Fields
Template:
x Address Old
House Number
795
Street Name
Lakeview
Street Type
Parkway
Address
795 Lakeview Pkwy
Document Type
Septic
PIN
0611723430014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
h <br /> � 1�C9� C�/�Z�� �S���G �n/4-r SF.PTIC PEY OF ORONO <br /> � /� INSPF.CT R IT PL B IEW <br /> '`_' Iz5� �v�/" �a�� DATE /Z/ <br /> PERMIT NO.S��j <br /> p� 0 nr�r�ao��r;n ns s�;r��irrrn <br /> 1� ��3 �Q7`i� �/� � AP('ROl'IiD WIT}I C'URRF,CTIOn9 AS NOTBD <br /> � 1�'O'1�nPPRU�'F.I)-CORkECT 8z RF.St;B�t(T <br /> � .��;i�arc fur your infonnation. All work sliall hc done <br /> �c ihl� uptic uid zoning cudc. <br /> Joseph Olson D.B.A. � �� �� � , ; � ��.:�,�„�,.��,�W. <br /> Rusty Olson's--Soil and Percolation Testing ����� � �� � <br /> Joseph J. Olson--MPCA License #810 <br /> 11481 Riverview Rd. NE, Hanover, MN 55341 �, : �t;. <br /> (763) 498-8779 Fax (763) 498-8290 <br /> �� <br /> ��� <br /> ��� <br /> � <br /> October l,2015 � �� �� ����� � �D,,.�-v���� <br /> Gonyea Homes <br /> Lot 3, Block 2 Lakeview of Orono <br /> Orono, Hennepin County <br /> This on-site Sewage Treatment System is designed for a Type I, five bedroom home in accordance with the <br /> Minnesota Pollution Control Agency Chapter 7080 and local ordinances. <br /> The periodically saturated soils were located at 26 inches(mottled soil). Due to the periodically saturated <br /> soils,a pressurized mound system with 6 inches of rock will need to be installed to treat the septic effluent. <br /> The bottom of the treatment area must be located at least 3' above the saturated soils. This system is <br /> designed with 6 inches of rock. <br /> The soils at a depth of 12"have a percolation rate averaging 8.7 MPI. <br /> All tanks need to be insulated if there is less than two feet of cover over the top of the tanks. Clean outs <br /> must be installed on the end of the laterals for maintenance. <br /> Use 7/32 inch perforations on the laterals. <br /> A 1300 gallon pumping chamber will need to be installed to lift the effluent to the treatment area. The <br /> power supply and Switches must be located outside the manhole and pumping chamber in a weatherproof <br /> enclosure. A warning device must be installed with light and sound devices;this is in case of a pump <br /> failure. The manifold and supply line must have back drainage to the pumping chamber. <br /> Keen all heavv epuipment off of the nroposed treatment areas before durine and after construction <br /> The area around both sites must be fenced off bv the contractor before anv construction be�ins <br /> With proper installation and maintenance,this system should have no problem in treating septic effluent <br /> effectively. Nothing other than gray water, (laundry, showers,etc.)Human water and toilet tissue should be <br /> disposed of into the septic tanks. Garbage disposals are not recommended. Additives must not be used they <br /> may cause harmful damage to your septic system. It is recommended that you pump the septic tanks every <br /> two years. <br /> Si rely, <br /> Joseph J. Olson TH1S$YSTEM IS DESIGNED FOR <br /> ..�,�BEDR�OMS. ANY INCREASE tN NUMBER <br /> �F BEDROOMS INVALIDATES tHIS DESlGN. <br />
The URL can be used to link to this page
Your browser does not support the video tag.