My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic design-general approval
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
780 Lakeview Parkway - 06-117-23-43-0021
>
Septic
>
septic design-general approval
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:29:14 PM
Creation date
4/24/2017 2:03:03 PM
Metadata
Fields
Template:
x Address Old
House Number
780
Street Name
Lakeview
Street Type
Parkway
Address
780 Lakeview Pkwy
Document Type
Septic
PIN
0611723430021
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
! <br /> INSPECTOR CHECKLIST - mound <br /> /tiU Lakev�ew Narkway <br /> � WELL setbacl:s: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 10d'to dispe�sal area with shallow well <br /> PROPERTY LINES secback: 10'to everything <br /> Road setback: platted: 10'prop line. Metes£c bounds: out of road easement, or outer ditch. <br /> LAKE/BLIiFF se�back: 20'for btuff. Lakes: GD_, RD_, NE Protected wetland <br /> Building setbacks: 70'for everything, 20'for dispersai area. <br /> WATER LINE under pressure se 10'to bed,tank£t sewer line. (else sewer iine � 12"betow) <br /> � Sewe�line Ft baffle connection (no 90's, 3'between 45's, slope min 1"in 8', max 2"in 8') <br /> (no depth req's, clean out every 100', Sch 40 pipe) <br /> � Septic tank and risers {water tight, insulated, proper depth, existing verified by pumping) <br /> mfg 2250 gatlons none <br /> Riser over outlet, riser over inlet or center, and 6"+inspection pipe over any remaining baffles. <br /> No effluent filter Ft alarm <br /> Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br /> mfg 1300 �atlons <br /> � dose pump 36 gpm 19 head VERIFY PUMP CURVE 5.b min ON 9 hr OFF <br /> � float setting drop 7.9 inches at 25.5 gpi "DESIGNED" 5.0 inches approx float tether length <br /> 202.0 gat dose divided by gpi "INSTALLED"= inches float drop(field correctetl <br /> LABEL pump requirements and drawdawn on riser or panel <br /> Cam lock reachable from grade- 30" max. J-hook weep hote. Supply line access (no hard 90's) <br /> 2.0 inch supply pipe; Sch40, stoped 1/8"+, supparted by 4"sch40 sleeve or compacted, and buried 6"+. <br /> splice box/ controt pane[! electricat eonnectfons <br /> flow measurement: CT, ETM, time dosed, home water meter <br /> mound absorption area rough up <br /> mound rock dimensions 10,0 X 63.0 <br /> Sand tift depth 14 inches. (Jar test: 2"sand leaves< 1/8"silt after 30 min) <br /> � Absorption Sand beyond rock 0.0 upslope 17.0 downslope <br /> � Bermed topwil beyond rockbed 9 upslope 13 sideslope 21 downslope <br /> cover depth of 12-18"+ VERIFY <br /> 3 laterats (1-2'from edge of rock) <br /> 2.00 inch pipe size (Sch40 pipe Ft fittings) <br /> 3A ft tateral spacing <br /> 8 7/32 inch perforations <br /> 3.0 ft perfaration spating <br /> Air intet at end of laterals, and at top feed manifotd if necessary, VERIFY <br /> clean outs (no hard 90's) <br /> 4"inspection pipe to bottom of rock, anchored VERIFY <br /> Abandon existing system - if necessary �Re-use existing tank certifitation <br /> monitoring ptan and type <br /> wetl abandonment form - if necessary <br />