My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-00014 - COO
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
725 Lakeview Parkway - 06-117-23-34-0008
>
Permits/Inspections
>
2017-00014 - COO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:26 PM
Creation date
4/19/2017 1:24:05 PM
Metadata
Fields
Template:
x Address Old
House Number
725
Street Name
Lakeview
Street Type
Parkway
Address
725 Lakeview Pkwy
Document Type
Permits/Inspections
PIN
0611723340008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Directions-The Minnesota Fuel Gas Code method to calculate to size of a requfred combustion air opening,is called the Known Air <br /> Infiltration Rate Method.For new construction,4b of step 4 is required to be flilled out. <br /> IFGC Appendix E,Worksheet E-1 <br /> Residential Combustion Air Calculation Method <br /> (for Furnace,Boiler,and/or Water Heater in the Same Space) <br /> Step 1:Complete vented combustion appliance information. <br /> Furnace/Boiler: .�00000 <br /> raft Hood �an Assisted �irect Vent Input: Btu/hr or Power Vent <br /> water Heater: 400�� <br /> raft Hood �Fan Assisted �ired Vent Input: Btu/hr or Power Vent <br /> Step 2:Calculate the volume of the Combustion Appliance Space(CAS)containing combustion appliances. <br /> The CAS includes ail spaces connected to one another by code compliant openings. CAS volume: 720 fta <br /> LxWxH 10 L S�W 9�H <br /> Step 3:Determine Air Changes per Hour(ACH�1 <br /> Default ACH values have been incorporated into Table E-1 for use with Method 4b(KAIR Method).If the year of construction or ACH is not known,use <br /> method 4a(Standard Method). <br /> Step 4:Determine Required Volume for Combustion Air.(DO NOT COUNT DIRECT VENT APPLIANCES) <br /> 4a.Standard Method <br /> Total Btu/hr input of all combustion appliances Input: Btu/hr <br /> Use Standard Method column in Table E-1 to find Total Required TRV: fta <br /> Volume(TRV) <br /> If CAS Volume(from Step 2)is gre a t er th a n TRV then no outdoor openings are needed. <br /> If CAS Volume(from Step 2)i s less th on TRV then go to STEP 5. <br /> 4b.Known Air Infikretion Rate(KAIR)Method(DO NOT COUNT DIRECT VENT APPLIANCES) <br /> Total Btu/hr input of all fanassisted and power vent appliances Input: 4�� Btu/hr <br /> Use Fan-Assisted Appliances column in Tabie E-1 to find RVFA: �OOO ft3 <br /> Required Volume Fan P�ssisted(RVFA) <br /> Total Btu/hr i�put of all Natural draft appliances Input: � Btu/hr <br /> Use Natural draft Appliances column in Table E-1 to find RVNFA: � fts <br /> Required Volume Naturel dreft appliances(RVNDA) <br /> Total Re uired Volume TRV =RVFA�RVNDA TRV= �OOO + O _ �000 TRV ft3 <br /> Step 5:Calculate the retio of available interior volume to the total required volume. <br /> Ratfo=CAS Volume(from Step 2)di vlded by TRV(from Step 4a or Step 4b) <br /> Ratio= 720 / 3000 = 0.24 <br /> Step 6:Calculate Reduction Factor(Rf�. <br /> RF=1 min us Ratio RF=1- O.�`'f = O.�" <br /> Step 7:Calculate single outdoor opening as if all combustion air is from outside. 40000 <br /> Total Btu/hr input of all Combustion Appliances in the same CAS Input: Btu/hr <br /> (EXCEPT DIRECT VENT) <br /> Combustion Air Opening Area(CAOA): <br /> Total Btu/hr d i vi d ed by 3000 Btu/hr per inz CAOA= 4���0 /3000 Btu/hr per in:= ��.�� inz <br /> Step 8:Calculate Minimum CAOA. <br /> Minimum CAOA=CAOA mu/tiplied by RF Minimum CAOA= �3.33 x o.76 = 10.�3 ��2 <br /> Step 9:Calculate Combustion Air Opening Diameter(CAOD) <br /> CAOD=1.13 m ultlplled by the squ ore root oJ Minimum CAOA CAOD=1.13�Minimum CAOA= 3'S9 in.diameter go up one inch in size <br /> if using flex duct <br /> 11f desired,ACH can be determined using ASHRAE calculation or blower door test.Follow procedures in Section <br /> G304. <br />