Fthvac-Residerrtiai-&tight Commerciaf H1/AC Lo�tls .�lite S�ftware Developm�nt,.lnc.
<br /> Sabre#�aurnbin9&'t�eating ' ; � 7�5 i.akevieYv F�ar�cwaY�rono,Mn Ru�in Residence.
<br /> , #�'m' MN � 7 � �: �a �
<br /> TotalBuildin Summa Loads
<br /> �r�� . � A�ea. S� �; .:�� �i < ��taJ
<br /> . _ y
<br /> w
<br /> �t.�s _ �t:,,, � _ �; Qi��n �� � �' arn_ `� ,��t�;�
<br /> LOW EE: Glazing-Builder Grade Low E Windows& 691.8 19,269 0 16,130 16,130
<br /> Sliding Door.32 U value .30 SHGC, u-value 0.32,
<br /> SHGC 0.3
<br /> 11J: Door-Metal-Fiberglass Core 163.6 8,540 0 2,356 2,356
<br /> R-20 12F-Osw: Wall-Frame, Custom, no board insulation, 3248.6 18,654 0 2,853 2,853
<br /> siding finish,wood studs
<br /> 15A-10sffc-8: Wall-Basement, concrete block wall, R-10 819 3,251 0 72 72
<br /> foam board to floor, no framing, no interior finish,
<br /> filled core, 8'floor depth
<br /> RJ R20 Closed Cell:Wall-Frame, Custom, Spray Foam R- 520.5 2,261 0 403 403
<br /> 20
<br /> R49- 166-49: Roof/Ceiling-Under Attic with Insulation on 1979 3,960 0 2,185 2,185
<br /> Attic Floor(also use for Knee Walls and Partition
<br /> Ceilings), Custom, R49 Blown Insulation-vented
<br /> attic, asphalt shingles
<br /> 21A-20-c: Floor-Basement, Concrete slab, any thickness, 1998 4,693 0 0 0
<br /> 2 or more feet below grade, no insulation below floor,
<br /> ______capet_.coverin.g,shortest side of floor slab__is 20'wide
<br /> - -__ __ _...__ _ _._...- __--
<br /> Subtotals for structure: 60,628 0 23,999 23,999
<br /> People: 6 1,200 1,380 2,580
<br /> Equipment: 901 4,116 5,017
<br /> Lighting: 1250 4,263 4,263
<br /> Ductwork: 0 0 0 0
<br /> Infiltration:Winter CFM: 15, Summer CFM: 0 1,354 0 0 0
<br /> Ventilation:Winter CFM:210, Summer CFM: 210 7,799 4,873 1,165 6,038
<br /> Humidification (Winter)22.23 gal/day : 8,154 0 0 0
<br /> AED_Excursion:__.... __.___..,
<br /> __... ___ _..... _..0 - ._. 0..... _1,275.._..... ___1 a275._
<br /> _ _...... _.....__ __...._
<br /> Total Building Load Totals: 77,935 6,974 36,198 43,171
<br /> - �.��- �,
<br /> . �_ .. . . . . . ... . ..... , ,
<br /> , ,
<br /> Total Building Supply CFM: 1,641 CFM Per Square ft.: 0.275
<br /> Square ft. of Room Area: 5,975 Square ft. Per Ton: 1,661
<br /> Volume(ft3)of Cond. Space: 53,775
<br /> Total Heating Required Including Ventilation Air: 77,935 Btuh 77.935 MBH
<br /> Total Sensible Gain: 36,198 Btuh 84 %
<br /> Total Latent Gain: 6,974 Btuh 16 %
<br /> Total Cooling Required Including Ventilation Air: 43,171 Btuh 3.60 Tons (Based On Sensible+Latent)
<br /> ' s� . . .� _ „ .u, .�. . �, � r �
<br /> _. . � , _ .,.- . ., , ,
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are pertormed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> your design conditions.
<br /> M:\...\725 Lakeview Parkway Orono REVISED 1-6-17.rh9 Friday,January 06, 2017, 12:33 PM