Laserfiche WebLink
06200 Finish Carpentry <br /> Doors, windows,base and other areas as per plan shall be trimmed out with <br /> standard Landschute design in birch and poplar material so that all trim <br /> is square and true. Interior doors shall be 6 panel hemlock material with birch <br /> veneer jambs or °French" type doors as per plan. <br /> Division 7-THERMAL AND MOISTURE PROTECTION <br /> 07I00 WaterproofinQ <br /> Exterior concrete walls below grade shall be coated with Koch brand "Tuff-n-Dry" material <br /> and covered with Koch brand "Warm-n-Dry" ridged insulation board. Said system shall be <br /> used in conjunction with a drain tile system. <br /> 07200 Insulation <br /> Exterior 2 x 6 wood-framed walls shall be insulated with R-19 fiberglass batts between � <br /> studs. 6 mil poly vapor barrier shall be taped at all joints with all bypasses being foamed. <br /> Roof insulation shall be blown fiberglass of an R-value of approximately 44 except in <br /> vaulted areas which will require hand-batting with an achieved R-value of 24 to 38. <br /> 07300 Shingles and Roof Tiles � <br /> Roofing shall be of hand-split cedar shakes applied over asphalt felts with a modified <br /> bitumen overlayment at eaves. <br /> 07400 Wood SidinQ <br /> Exterior walls shall be covered with 15#felt underlayment under cedar shingles. <br /> 07631 Gutters and Downspouts <br /> Half-round copper gutters shall be installed along appropriate eaves with downspouts <br /> provided as necessary. <br /> Division 8-DOORS and WINDOWS <br /> 08200 Exterior poors <br /> Entry door from house to garage shall be solid core wood panel door with deadboft lock <br /> and lever handle. <br /> 08361 Sectional Wood Overhead Doors <br /> Garage doors shall be of painted, wood-panel doors with top row of glass lites and <br /> individual openers. Door shall be insulated and overlaid wi[h beadboard paneling. <br /> 08600 Wood Windows <br /> Windows shall be of primed ponderosa pine sash and fi•ame, double-hung type. Glass shall <br /> be insulating type with low emissivity coating. <br /> 08700 Hardware <br /> All interior door hardware shall be polished brass lever type. Entry hardware shall be of <br /> polished brass "Lexington"by Baldwin. <br /> Division 9-FINISHES <br /> 09250 Gypsum Dr�wall <br /> All vertical walls shall be of 1/2" gypsum board screwed and nailed with taped <br /> joints sanded smooth. All interior ceilings shall be of 5/8" gypsum board screwed <br /> with taped joints. Ceiling texture[o be smooth. <br /> 09310 Ceramic Tile <br /> Allowance to provide for ceramic tile as per plan. <br /> 09550 Wood Floorin� <br /> Areas not floored with carpet or ceramic tile shall be floored witll lx8 #2 pine flooring to <br /> run perpendicular to floor joists. Floor shall be antiqued, dis[ressed, and finished with <br /> heavy-duty satin finish urethane coating. <br /> 09680 Carpeting <br /> Provide for the carpeting for area not covered with wood or ceramic tile. <br /> 09900 Painting <br /> Exterior trim and siding shall be coated with one coat Benjamin Moore Alkyd based primer <br /> and two final coats of Benjamin Moore"moorglo" latex enamel--colar <br /> �5 7 5 �v�e...s�i ��i,��t �� <br />