Laserfiche WebLink
% MEMBER REPORT Second Floor,False Wdw Hdr PASSED <br /> .JFORTE � <br /> 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 <br /> Overall Length:6'6" <br /> . d j-�'e �M;S`�v }baN� "�v4 <br /> . .n,-r-...'..r. uy . q� �. : . ...:. . <br /> :.. <br /> - ...y+. _ . ... <br /> + + <br /> � � <br /> s� <br /> � � <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> Desi n Results Acpwl @ Location Allowed Resuk LDF Load:Combination(Pattem) System:Wall <br /> Member Reaction Qbs) 805 @ 1 1/2" 3825(3.00") Passed(21%) -- 1.0 D+1.0 S(All Spans) ' hlember Type:Header <br /> Shear(Ibs) 552 @ 1'1/4" 2872 Passed(19%) 1.15 1.0 D+ 1.0 S(All Spans) euilding Use:Residentlal <br /> Moment(Ft-Ibs) 1209 @ 3'3" 3946 Passed(31%) 1.15 1.0 D+1.0 S(All Spans) Buiiding Code:IBC <br /> Live Load DeFl.(in) 0.011 @ 3'3" 0.208 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) oesign Methodology:nSo <br /> �Total Load DeFl.(in) 0.031 @ 3'3" 0.313 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) <br /> •DeFlection criteria:LL(L/360)and TL(L/240). �� <br /> •Bracing(Lu):All compression edges(top and bottom)must be braced at 6'6"o/c unless detailed othenvise.Proper attachment and positioning of laterdl <br /> bracing is required to achieve member stability. <br /> •Applicable calculations are based on NDS 2005 methodology. <br /> � <br /> Bearing Loads to Supports(Ibs) ''. <br /> '��.SUpp01't5 7ota1 Available Required Dead Snow To�l Accessories <br /> 1-Trimmer-SPF 3.00" 3.00" 1.50" 520 284 804 None <br /> I 2-Trimmer-SPF 3.00" 3.00" 1.50" 520 284 804 None <br /> -- — --- -- _.__— .._...-� <br /> Tribubry Dead Snow <br /> �,LOa(�5 Location Width (0.90) (1.15) Comments �� <br /> 1-Uniform(PSF) 0 to 6'6" 2'6" 21.2 35.0 roof <br /> 2-Uniform(PLF) 0 to 6'6" N/A 100.0 - gable <br /> i... — --- ---- -- --- <br /> 'Weyerhaeuser Notes �SUSTAINABLE FORESTRY WRIATIVE <br /> Weyerhaeuser warrantr that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. <br /> Weyerhaeuser eupressly dixlaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. <br /> (www.woodb�y.coml Accessories(Rim Board,Blxldng Panels and Squash Blxks)are not designed by this software.Use of this software is not intended to <br /> circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable <br /> forestry standards. <br /> The product applicatlon,input design loads,dimensions and support information have been provided by Forte Software Operator <br /> Forte Software Opereror ,lob Notes 7/10/2014 10:12:19 AM <br /> ' Ryan Fr tz Gonyea Homes Forte v4.6,Design Engine:V6.1.1.5 <br /> � Lyman Lumber company MIIIer Residence 195{�111CJ/Y@ L817B.4r@ <br /> (952j 470-4803 195 Kintyre Lane <br /> Rvan Fritz@iymanwmber.com Orono.MN �isi2o�a Page 7 of 43 <br />