My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-01088 - new mound system septic
Orono
>
Property Files
>
Street Address
>
K
>
Kintyre Lane
>
195 Kintyre Lane - 32-118-23-43-0015
>
Septic
>
2014-01088 - new mound system septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:41:48 PM
Creation date
4/12/2017 2:24:52 PM
Metadata
Fields
Template:
x Address Old
House Number
195
Street Name
Kintyre
Street Type
Lane
Address
195 Kintyre Lane
Document Type
Septic
PIN
3211823430015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� _ OSTP Mound Design UNIVERSITY ' `' `` = <br /> Minnesota Pollution Worksheet >1 % Stope OF MINNESOTA n;'���� `"� <br /> Control Agency �'1.'�� <br /> 1. SYSTEM SIZING: Project ID: v 06.12.13 <br /> a. Design Flow: 750 GPD TABLE IXa <br /> B. Soil Loading Rate: O.GO GPD/ftZ LOADING RATES FOR DETERMINING 807TOM ABSORPTION AREA <br /> AND A850RPTION RATIOS USING PERCOI.ATION TESTS <br /> �Treatment Levet C Trcatment Level A,A•2,B, <br /> C. Depth to Limiting Condition: 2.0 ft <br /> Perwlation tlate �S°rptlon Abwrption <br /> Area Lwding �11Dund Area Loading �"�Ound <br /> D. Percent Land Stope: 3.0 % ��'''� Rac� Abwrpdon Rate �'S°��°" <br /> ���ft1� Ratio (���� Ratio <br /> E. Design Media Loading Rate: 1.2 GPD/ft2 .o, . 1 _ � <br /> F. Mound Absorption Ratio: 2.00 0„°s �.2 1 1.6 , <br /> 0�to 5(tine sand 0.6 2 1 1.6 <br /> Tabl2 I and toam �ne sand) <br /> �AOUND CONTOUR LOADIPIG RATES: s to�s o.�s �.s 1 �.6 <br /> Contour �s to so 0.6 2 0.78 2 <br /> Measured ' Tsz[ure-d?rivcd �oad.�o 3�to-0s o.s 2.a o.�e 2 <br /> Perc Rato �R mound absorption ratio ' <br /> �t°� 46 to 60 0.45 2.6 0.6 2.6 <br /> �h0�1p1 1.0, 1.3.2.0, 2.J. 2.5 <�2 61to 120 • 5 0.3 5.3 <br /> , >i2o - • - - <br /> 61•t 20 mpi oR s.o =t2 kSystems with these values are not Type I systems. <br /> �12o mpi' >5.�• ,,�. Contour Loading Rate(linear loading rate}is a <br /> recommended value. <br /> 2. DISPERSAL MEDIA SIZING <br /> A. Calculate Dispersal Bed Area: Design Flow=Design Media Loadin�Rate=ftZ <br /> 750 GPD : 1.2 GPD/ft2 = 625 ftZ <br /> If a larger dispersal media area is desired, enter size: 630 ftZ <br /> B. Enter Dispersat Bed Width: 90.0 ft Can not exceed f0 feet <br /> C. Calculate Contour Loading Rate: Bed Width X Design Media Loading Rate <br /> 10 ft2 X �•2 GPD/ft� = 12.0 gal/ft Can not exceed Tabte 1 <br /> D. Calculate Minimum Dispersal Bed Length: Dispersat Bed Area :Bed Width =Bed Length <br /> 630 ft2 ; 10.0 ft = 63.0 ft <br /> 3. ABSORPTION AREA SIZiNG <br /> A. Catcutate Absorption Width: Bed Width X Mound Absorption Ratio =Absorption Width <br /> 10.0 ft X 2.0 = 20.0 ft <br /> B. For slopes>1%, the Absorption Width is measured downhill from the upslope edge of the Bed. <br /> Catculate Downslope Absorption Width:Absorption Width - Bed Width <br /> 20.0 ft - 10.0 ft = 10.0 ft <br /> 4. DISTRIBUTION MEDIA: ROCK <br /> A. Media Volume: Media Depth X Length X Width <br /> 1.00 ft X 63.0 ft X 10.0 ft= 630 ft3 : 27 = 23 yd3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.