My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-01088 - new mound system septic
Orono
>
Property Files
>
Street Address
>
K
>
Kintyre Lane
>
195 Kintyre Lane - 32-118-23-43-0015
>
Septic
>
2014-01088 - new mound system septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:41:48 PM
Creation date
4/12/2017 2:24:52 PM
Metadata
Fields
Template:
x Address Old
House Number
195
Street Name
Kintyre
Street Type
Lane
Address
195 Kintyre Lane
Document Type
Septic
PIN
3211823430015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MinnesotaPollution OSTP Design Summary Worksheet UNIVERSITY " J � �� <br /> r;r �....�� � _- <br /> tontrol Agency OF MINNESOTA '�:;��J <br /> Property Owner/Client: Gonyea Homes Projed ID:��v 06.12.13 <br /> Site Address: 195 Kinty�e Lane,Orono,Hennepin County Date:� <br /> 1. DESIGN FLOW AND TANKS <br /> A. Design Flow: 750 Gallons Per Day(GPD) Nofe: The estimated design ftow is considered a peak flow rate <br /> including n sofery factor.For long term performance,the average <br /> B. Septic Tnnks: daily ftow is recommended to be<60%of this velue. <br /> Minimum Code Required Septic Tank Capacity: 2250 Gallons,in �Tanks or Compartments <br /> Recommended Septic Tank Capacity: 2250 Gallons,in ��Tanks or Compartments <br /> Efftuent Screen: No Alartn: No <br /> C. Nolding Tanks Only: <br /> Mi�imum Code Required Capacity:�—�Gallons,in ��Tanks <br /> Designer Recommended Capacity:C�Gallons,in ��Tanks <br /> Type of High Level Alarm: <br /> D. Pump Tank 1 Capacity(Cade Minimum):�Gallons Pump Tank 2 Capacity(Code Minimum): �Gallons <br /> Pump Tank 1 Capacity(Designer Rec): �—�Gailons Pump Tank 2 Capacity(Designer Rec): ��Gallons <br /> Pump 1 36.0 GPM Total Head 37.1 ft Pump 2��GPM Total Head �ft <br /> Supply Pipe Dia. 2.00 in Dose Volume:��gal Supply Pipe Dia.C�;n Dose Votume:C�ga� <br /> 2. SYSTEM TYPE <br /> Type of Soil Treatmen[and Oispersal Area* r <br /> � hench Q Bed QQ Mound I �Grevlty Distr�utlan QQ Raaae Dlstribution-l.evel Q Pressure Distrbutlon-I.kdevel <br /> Q Drip Q Holding Tank O At-Grade 'Selection Required Benchmark Elevation: 1054.0 ft <br /> Benchmark Location: Topo map <br /> System Type <br /> Type of Distribution Media: <br /> 0 Type I ❑Type I{ ❑Type III �Type I V ❑Type V 0 Dreinfietd Rock �Registered 7reatrneM Media: <br /> 3. SITE EVALUATION: <br /> A. Depth to Limiting Layer: 24 in 2.0 ft B. Measured Land Slope%: 3.0 % <br /> C. Elevation of Limiting Layer:� 1052.4 D. Soil Texture: Loam—� <br /> E. Loc.of Restricive Elevation: F. Soil Hyd.Loading Rate• 0.60 GPD/ft� <br /> G. Minimum Required Separation:C�in. �ft H. Perc Rate: 6.0 MPI <br /> 1. CodeMaximum Depth of System:��9� Comments: <br /> 4. DESIGN SUMMARY <br /> Trench Design Summary <br /> Dispersal Area��ftz Sidewall DepthC��n Trench Width��� <br /> Total Lineal Feet�ft Number of Trenches� Code Maximum Trench Depth���� <br /> Contour Loading Rate��ft Designers Max Trench Depth�—�in <br /> Bed Design Summary <br /> Absorption Area�_�ft2 Media Below PiPe�in Code Maximum Bed Depth�in <br /> Bed Width��ft Bed Length��ft Designers Max Bed Depth�in <br />
The URL can be used to link to this page
Your browser does not support the video tag.