My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-01088 - new mound system septic
Orono
>
Property Files
>
Street Address
>
K
>
Kintyre Lane
>
195 Kintyre Lane - 32-118-23-43-0015
>
Septic
>
2014-01088 - new mound system septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:41:48 PM
Creation date
4/12/2017 2:24:52 PM
Metadata
Fields
Template:
x Address Old
House Number
195
Street Name
Kintyre
Street Type
Lane
Address
195 Kintyre Lane
Document Type
Septic
PIN
3211823430015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIl�ED <br /> ��� �� 2014 <br /> CI1Y 0�ORONO� <br /> Joseph Olson D.B.A. <br /> Rusty Olson's--Soil and Percolation Testing <br /> Joseph J. Olson--MPCA License#S10 <br /> 11481 Riverview Rd. NE,Hanover,MN 55341 <br /> (763) 498-8779 Fax(763)498-8290 <br /> Revised July 23,2014 <br /> November 03,2005 <br /> Gonyea Homes <br /> 195 kintyre Lane <br /> Orono,Hennepin County <br /> This on-site Sewa�e Treatment System is desia ed for a Type 1,Five-Uedroom home in accordance with <br /> the Minnesota Pollution Control Aaency Chapter 7080 and local ordinances. <br /> The periodically saturated soils were located at 18"-32"(mottled soil).Due to the periodically saturated <br /> soils,a pressurized mound system will need to be installed to treat the septic effluent.The bottom of the <br /> treatment area must be located at least 3'aUove the saturated soils. <br /> The soils at a depth of 12"have a percolation rate averaging 6 MPI. <br /> All tanks need to be insulated if there is less than two feet of cover over the top of the tanks.Clean outs <br /> must be installed on the end of the laterals for maintenance. <br /> Use 7/.i2 inch perforations on the laterals. <br /> All nei�hboring wells are greater th� l00' from proposed treatment areas. <br /> A 1300 gallon pumpin�chamber will need to be installed to lift the effluent to the treatment area.Tl�e <br /> power supply and Switches must be located outside the manhole and pumpin�chamber in a weatherproof <br /> enciosure.A warning device must be installed with light and sound devices;this is in case of a pump <br /> failure.The manifold and supply]ine must have back draina�e to the pumpin;chamber. <br /> Keep aH heavv equipment off o1'the proposecl treatment areas before durinQ and after construction <br /> The area around both sites must be fenced off bv the contractor before anv construction be�ins <br /> With proper installation and maintenance,this system should vave no problem in treating septic effluent <br /> effectively.Nothing other than gray water,(laundry,showers,etc.)Human water and toilet tissue should be <br /> disposed of into the septic tanks. Garbage disposals are not recommended.Additives must not be used they <br /> may cause harmful dama�e to your septic system. It is recommended that you pump the septic tanks every <br /> two years. <br /> SincereJ � <br /> � <br /> % <br /> �-- t�r oF oRONa <br /> Joseph J.Olson $E1'TI[�pERMtT PL�1N RBVIEW <br /> TNSPECTOR� <br /> DATB�„r,,,, BRMIT N(�, <br /> PROVED AS 9IlN1dt7'TBp <br /> APPROYED WITH C(NtRF.CTiONtS Ils}QOTBO <br /> ����' ,���� NOT A!'t'ROYED�CORR�CT S RESUBNtt <br /> BEDRUONtS� �'�tt�ASE A�f tn����.�.n��+.�r�w.. �ut.��.�,.n waw�. <br /> � la fall�.ompitasoo witt�all app!{cabls�eptio anet maiag cocfr. <br /> ��������`� Requiramenlc iec{udin�itean nw ipecilicr(lY noted b Iliiaa�rirllh <br /> K�EP 7'1ji�FLAK i6T W8 sITiB AT Md.?'IAi� <br />
The URL can be used to link to this page
Your browser does not support the video tag.