Laserfiche WebLink
� , <br /> �:� ����#��� , ���er <br /> �� ,,�� � '��h'�� ,�, <br /> Total Buildin Summa Loads <br /> Low EE:Giazing-LowEE Builder Grade .31 U-value, .29 884.5 23,853 0 21,275 21,275 <br /> SHGC, Window and Patio Door, u-value 0.31, SHGC <br /> 0.29 <br /> 11J: Door-Metal-Fiberglass Core 69.3 3,620 0 1,124 1,124 <br /> 15A-10sffc-8:Wall-Basement,concrete block wall, R-10 1306.5 5,186 0 148 148 <br /> foam board to floor, no framing, no interior finish, <br /> filled core, 8'floor depth <br /> 15A-10sffc-4:Wall-Basement, concrete block wall, R-10 114 496 0 0 0 <br /> foam board to floor, no framing, no interior finish, <br /> filled core,4'floor depth <br /> R20 12F-Osw: Wall-Frame,Custom, R-20 Insulation in 5153.5 29,592 0 5,543 5,543 <br /> 2x6 Cavity, no board insulation, siding finish,wood <br /> studs <br /> RJ 20 Spray Foam:Wall-Frame, Custom, Rim Joist R-20 717.4 3,122 0 985 985 <br /> Closed Cell Spray Foam <br /> R49 166-49: Roof/Ceiling-Under Attic with Insulation on 3146.9 6,297 0 3,690 3,690 <br /> Attic Fl�r(also use for Knee Walls and Partition <br /> Ceilings), Custom, R-49 Blown Insulation, No <br /> Radiant BaRier,Vented Attic,Asphalt Shingles <br /> 21A-32: Floor-Basement, Concrete slab,any thickness,2 1848 3,216 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 32'wide <br /> 21A-28: Floor-Basement, Concrete slab,any thickness, 2 725 1,388 0 0 0 <br /> or more feet below grade, no insulation below floor, . <br /> any floor cover, shortest side of floor slab is 28'wide <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 27 82 0 10 10 <br /> R-30 blanket insulation,any cover <br /> 20P-38: Floor-Over open crawl space or garage,Passive, 534 1,393 0 176 176 <br /> R-38 blanket insulation,any cover <br /> Subtotals for structure: 78,245 0 32,951 32,951 <br /> People: 6 1,200 1,380 2,580 <br /> Equipment: 901 4,116 5,017 <br /> Lighting: 0 0 0 <br /> Ductwork: 4,141 476 1,090 1,566 <br /> Infiltration:Winter CFM: 117,Summer CFM: 0 10,887 0 0 0 <br /> Ventilation:Winter CFM:226, Summer CFM:226 8,394 6,210 1,544 7,754 <br /> Humidification(Winter)25.41 gal/day : 9,319 0 0 0 <br /> AED Excursion: 0 0 5 486 5 486 <br /> Total Building Load Totals: 110,986 8,788 46,567 55,354 <br /> �� �"�� ;'3���� +. ``���- Ft�:; <br /> ,. ,. ., > ,e.� . ,. . .,..+ , ..� .. . � <br /> Total Building Supply CFM: 2,109 CFM Per Square ft.: 0.310 <br /> Square ft.of Room Area: 6,800 Square ft. Per Ton: 1,474 <br /> Volume(ft')of Cond. Space: 68,644 <br /> Total Heating Required Including Ventilation Air: 110,986 Btuh 110.986 MBH <br /> Total Sensible Gain: 46,567 Btuh 84 °� <br /> Total Latent Gain: 8,788 Btuh 16 % <br /> Total Cooling Required Including Ventilation Air: 55,354 Btuh 4.61 Tons(Based On Sensible+Latent) <br /> �.. <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> M:1Sales and Estimating\Heat Calcs\Gonyea\140 Kintyre Lane Orono WATKINS.rh9 Friday, June 12, 2015,2:01 PM <br />