<br /> Pro'ect Re ort
<br /> Project Title: 140 Kintyre Lane Orono WATKINS
<br /> Designed By: Michael Hoium
<br /> Project Date: Friday, June 12,2015
<br /> Client Name: Gonyea Homes
<br /> Client City: Golden Valley, MN
<br /> Company Name: Sabre Plumbing&Heating
<br /> Company Representative: Michael Hoium
<br /> Company Address: 15535 Medina Road
<br /> Company City: Plymouth, MN 55447
<br /> Company Phone: 763-473-2267
<br /> Company Fax: 763-473-8565
<br /> , .
<br /> . �k �� �.�
<br /> �'•-.� r.-"�. .;,., .�< � s � ,r. a ��'� �;��'"y.` :;s.r :
<br /> ,. ._ �a:: P.,._ , ���•. . ,, �_:.�.., . _ .
<br /> Reference City: Minneapolis, Minnesota
<br /> Building Orientation: Front door faces East
<br /> Daily Temperature Range: Medium
<br /> Latitude: 44 Degrees
<br /> Elevation: 834 ft.
<br /> Altitude Factor: 0.970
<br /> Outdoor Outdoor Outdoor Indoor Indoor Grains
<br /> D�y Bulb Wet Bulb B�L1�U�] $�LHUp] Dry Bulb Difference
<br /> Winter: -15 -12.38 Na 30% 72 29.40
<br /> Summer: 88 73 50% 50% 72 42
<br /> G � S{t. ' 3.?. a�^. ;�t'� ,UY`L[ .w`�` '� '� ��i;t" ;4�''?; '=` s
<br /> , . _ .. �..,. , n , x. ,. .*- r . . .> ..,:, .. .. ,... �. n ..-,..� ..,,�, -,..
<br /> Total Building Supply CFM: 2,109 CFM Per Square ft.: 0.310
<br /> Square ft.of Room Area: 6,800 Square ft. Per Ton: 1,474
<br /> Volume(ft�)of Cond. Space: 68,644
<br /> �y % < <� #�,,�. s �._
<br /> x ,��;
<br /> Total Heating Required Including Ventilation Air: 110,986 Btuh 110.986 MBH
<br /> Total Sensible Gain: 46,567 Btuh 84 %
<br /> Total Latent Gain: 8,788 Btuh 16 %
<br /> Total Cooling Required Including Ventilation Air: 55,354 Btuh 4.61 Tons(Based On Sensible+ Latent)
<br /> f � : �, ��� . .� � � � ��� -
<br /> �„ .. . ,.
<br /> , � �„
<br /> � « � ,�:, �_, r „ ..
<br /> �� �� � ������
<br /> � ;�. � � ;-
<br /> ,�._. �4�. . :� , ,�,
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> your design conditions.
<br /> M:\Sales and Estimating\Heat Calcs\Gonyea\140 Kintyre Lane Orono WATKINS.rh9 Friday,June 12, 2015,2:01 PM