2016-00290 - retaining wall
Orono
>
Property Files
>
Street Address
>
K
>
Kintyre Lane
>
140 Kintyre Lane - 32-118-23-43-0019
>
Permits/Inspections
>
2016-00290 - retaining wall
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:42:01 PM
Creation date
4/12/2017 9:50:04 AM
Metadata
Fields
Template:
x Address Old
House Number
140
Street Name
Kintyre
Street Type
Lane
Address
140 Kintyre Lane
Document Type
Permits/Inspections
PIN
3211823430019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orono, MN Code of Ordinances Page 1 of 3 <br /> Sec.58-50.-More restrictive design and construction standards. <br /> All ISTS permit applications,site evaluations,design specifications,construction methods,and material specifications <br /> shall meet the parts of Minnesota Rules chapter 7080 adopted by reference in section 58-43 with the following additional <br /> minimum standards: <br /> (1) Site evaluation.The site evaluation report shall include the following: <br /> a. Soi/borings.At least three soil borings shall be completed for each new drainfield site designed. Each soil <br /> boring must be located within the drainfield site or within close proximity along similar contours such that <br /> similar soil conditions are likely. For additions to an ISTS,at least one soil boring shall be made in the <br /> expansion area. <br /> b. Percolation iests.At least two percolation tests shall be completed for each new drainfield site designed. Each <br /> percolation test must be located within the drainfield site or within close proximity along similar contours <br /> such that similar soil conditions are likely.For additions to existing ISTS's,at least one percolation test shall <br /> be completed in the expansion area. <br /> c. Ploi plan.A scale drawing of the entire lot showing the following: <br /> 1. All property lines and lot dimensions. <br /> 2. All existing and proposed structures. <br /> 3. All existing or proposed well locations,or water supply piping. <br /> 4. Relative elevations of house,lot corners and drainfield areas. <br /> 5. Slope of ground at drainfield sites by contour lines or direction arrows and slope percentages. <br /> 6. Location of all percolation test holes and soil borings with identifying symbols and relative ground <br /> elevations of each. <br /> 7. Primary and alternate drainfield areas identified. <br /> 8. Distance from primary and alternate drainfield areas to property lines,well locations,and any lake, <br /> stream,marsh or drainage channel within 75 feet of any part of the system. <br /> (2) ISTS design. ISTS design specifications shall include proposed flows or other sizing information, minimum sewage <br /> tank capacity, minimum soil treatment area requirements,a plan of the component layout,and all other <br /> information necessary to assure the city that the ISTS is designed and will be constructed to receive,treat and <br /> dispose of all of the sewage from the building served. Footing or roof drainage,water softener recharge water, <br /> garage floor drainage,toxic chemicals,flammable liquids,animal wastes,commercial process water and <br /> commercial kitchen grease shall not enter any portion of the ISTS but shall be separately treated and disposed of <br /> according to the applicable regulations of the MPCA,the state board of health and the city. <br /> a. Setbacks.The minimum setback distance requirements are as follows: <br /> Feature Sewage Soil <br /> Tank Treatment <br /> (feet) Area <br /> Water supply <br /> well: <br /> Deep well 50 50 <br /> Shallow 50 100 <br /> wel I <br /> Wetland 50 50 <br /> La ke: <br /> about:blank 3/31/2016 <br />
The URL can be used to link to this page
Your browser does not support the video tag.