Technical Data: Note: <br /> � Orifice Size: 'h" (15mm) 1. The "A" dimension is based on a nominally gauged <br />, Thread Size: 1" NPT per ANSI B2.1 pipe thread "make-up" of 0.600" (15mm) per ANSI <br /> Working Pressure: 175 psi(12 bar) B2.1 [7'h threads approximately]. <br /> Nominal K Factor-US/(Metric):5.6/(80) 2. All platings and paintings are decorative and intend- <br /> Product Description ed for interior use. <br /> Reliable Model F3QR Dry Sprinklers are quick response General Installation Instructions <br /> sprinklers utilizing a durable 3mm frangible glass bulb. This Model F3QR dry sprinklers must be installed only in stan- <br /> quick response enables these sprinklers to apply water to a dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) <br /> fire much sooner than standard response sprinklers of the pipe tees in the horizontal position,even at branch line ends. <br /> similar temperature rating. They should not be installed into elbows or pipe couplings <br /> Model F3QR Dry Sprinklers are intended for use in dry and located on drop nipples to the sprinklers.For these and other <br /> preaction systems and in areas subjected to freezing tem- fittings including CPVC,the dry sprinkler should be installed <br /> peratures, such as freezers and unheated portions inside into a fitting to allow protrusion into the fitting in accordance <br /> and outside buildings. with the diagrams. The "A" dimension of the dry sprinkler, <br /> Environments wherein dry sprinklers are employed can which extends into the freezers or a freezing zone from wet <br /> be corrosive. For this reason, Model F3 Sprinklers have a p�pe systems,should be selected to provide,as a minimum, <br /> special wax fillet placed in the gap between the cup that the specified lengths in inches shown in Fig. 10. <br /> supports the bulb and the wrenching boss.This wax will not uti n: <br /> interfere with the operation of the sprinkler, and it prevents Do not install Model F3QR Dry sprinklers into CPVC adapt- <br /> contaminents from entering the internal portion of the drop er fittings or tees that have an internal obstruction. This will <br /> nipple.The wax must not be removed. damage the sprinkler and/or the fitting. Refer to Fig. 11. <br /> Operation <br /> The glass bulb consists of an accurately controlled amount During installation,the following steps must be followed: <br /> of special fluid hermetically sealed inside a precisely manu- <br /> factured glass capsule. This glass bulb is specially con- 1. Cut the specified size hole(see illustrations)for the sprin- <br /> structed to provide fast thermal response. When the tem- kler in the ceiling or wall directly in line with the tee. <br /> perature increases sufficiently,due to a fire,the bulb shatters 2. Apply pipe joint compound to the 1" (25mm) pipe <br /> allowing operating parts to clear the waterway. This enables threads and install sprinkler using the Model F3 or XL02 <br /> the inlet seal to release air or water and subsequently,cause Sprinkler Wrench as specified'. I <br /> water flow over the deflector in a uniform spray pattern,con- 3. Install the Model FP push-on /thread-off escutcheon or <br /> trolling or extinguishing the fire. CCP cover plate if required. <br /> Ordering Information Note:Installation of the Model F3QR Sprinklers is not recom- <br /> S eci mended in copper pipe systems,as this may reduce the life <br /> p �� expectancy of the sprinklers. <br /> 1. Sprinkler Type (select one): <br /> (a)Model F3QR Dry Pendent Modei F3QR Concealed and Recessed In- <br /> (b)Model F3QR Dry Pendent/HB <br /> (c)Model F3QR Dry Recessed FP Pendent stallation Instructions <br /> (d)Model F3QR Dry Recessed F1 Pendent • The Model XL02 wrench (Fig. 12) is designed to lo- <br /> (e)Model F3QR Dry Concealed Pendent cate on the wrenching pads of the recessed sprin- <br /> (f)Model F3QR Dry Horizontal Sidewall kler while centering in the cup'. A standard '/z" drive <br /> (g)Model F3QR Dry Horizontal SidewallMB ratchet may be used to drive this wrench. Fig. 13 and <br /> (h)Model F3QR Dry Recessed FP Horizontal Sidewall-UL Fig. 14 show sequentially the insertion of the wrench. <br /> (i)Model F3QR Dry Recessed F1 Horizontal Sidewall-UL First the wrench, with its jaws above the sprinkler de- <br /> &FM flector, is moved laterally until centered with the cup. <br /> 2. Sprinkler Temperature Rating. Then raise the wrench inside of the cup until its jaws <br /> 3. Sprinkler Finish. engage the sprinkler's square wrenching pads (Fig. <br /> 4. Escutcheon type (F1 or FP). 14). To remove the wrench, follow this procedure in <br /> 5. Cover Plate/Escutcheon Finish. reverse order. Care should be taken to avoid striking <br /> 6. Length: the deflector, with the wrench. <br /> "A"Dimension(face of tee to face of ceiling or wall)in 1/a" • Model F3 Wrench (Fig. 15) is used for installation of ( <br /> (6mm)increments. Pendent and Horizontal Sidewall sprinklers'. <br /> 7. Model F3QR Dry Pendent (a) is available without <br /> sprinkler can and escutcheon. <br /> ' Instailation Wrenches: <br /> Throughout this technical builetin,Reliable has specified specific installation wrenches for use on each version of our sprinklers.A pipe wrench may also <br /> be used to instail a dry sprinkler provided that it only interfaces with the steel outer tube of the assembly(Item#8 on fig 16). Keep in mind that a oioe <br /> wrench will incorporate a large amount of toraue into the final assembly This tor�ue will have to be matched or exceeded u�on the sprinkler's removal at <br /> a later date. <br /> 11. <br />