Laserfiche WebLink
Technical Data: F1 Res 49 Pendent and Recessed Pendent(SIN R3516) <br /> Thread NominalOrifice Max. Sprinkler Max. Actual Sprinkler <br /> Pressure Tem .Ratin Ambient Tem . K Length <br /> Size Inch(mm) si bar °F °C °F °C Factor Inch mm <br /> Yz"NPT ��,6^(11) 175(12) 155 68 100 38 4.9(70.6) 2.25(57) <br /> RYz 175 79 150 66 <br /> Ordinary Temp.Rating IrrE�rtr�ediafie Temp.Rating Top of Deflector Minimum <br /> Max.Coveroge area Max.Spacing 155°F/68°C 175°F/79°C to Ceilin9 Spaang <br /> Ft x Ft(m x m) Ft(m) Flow Pressure Flow Pressur�e <br /> GPM Umin PSI GPM Vmin PSI bar �nch(mm) Ft(m) <br /> 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48) 13(49) 7.0(0,48) Smooth Ceilings 1'/a to 4(31.7 to <br /> 102)using F2 escutcheon. <br /> 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) 13(49) 7.0(0,48) 1 to 4(25.4 to 102)using F1 <br /> escutcheon. <br /> 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) 13(49) 7.0(0,48) Beamed Ceilings per NFPA 8�2 4� <br /> 13D,13R or 13 installed in <br /> 18 x 18(5,5 x 5,5) 18(5,5) 17(64,3) 12(0,83) 17(64,3) 12(0,83) beams 1Ya to 13/a (31.7 to <br /> 44.4)using F2 escutcheon,1 <br /> 20x20(6,1 x6,1) 20(6,1) 20(75,7) 16.7(1,14) 20(75,7) 16,7(1,14) to13/a(25.4to44.4)usingFl <br /> escutcheon <br /> For Ceiling types refer to NFPA 13, 13R or 13D <br /> Ordinary Temp.Rating IMenr�ediate Temp.Rating Top of Deflector Minimum <br /> Max.Coverage ar� Max.Spacing 155°F/�8°C 175°F/79°C to Ceilin9 Spacing <br /> Ft x Ft(m x m) Ft(m) Flow Pressure Flow P��� Inch(mm) Ft(m) <br /> GPM Vmin PSI bar GPM Vmin PSI bar <br /> 12 x 12(3,6 x 3,6) 12(3,6) 15(57) 9.4(0,65) 15(57) 9.4(0,65) Smooth Ceilings 4 to 8(100 to <br /> 203)using F2 escutcheon. <br /> 14 x 14(4,3 x 4,3) 14(4,3) 16(60,5) 10.6(0,73) 16(60,5) 10.6(0,73) 4 to 8(100 to 203)using F1 <br /> escutcheon. <br /> 16 x 16(4,9 x 4,9) 16(4,9) 17(64,3) 12.0(0,83) 17(64,3) 12.0(0,83) Beamed Ceilings per NFPA 13D, 8(2,4) <br /> 13R or 13 instalied in beams <br /> 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 15.0(1,0) 19(72) 15.0(1,0) 4Ya to 8(108 to 203)using F2 <br /> escutcheon,4 to 8(100 to 203) <br /> 20 x 20(6,1 x 6,1) 20(6,1) 22(83,2) 20.2(1,4) 22(83,2) 20.2(1,4) using F1 escutcheon <br /> Technical Data: F1 Res 58 Pendent and Recessed Pendent(SIN R3513) <br /> Thread NominalOrifice Max. Sprinkler Max. p�ual Sprinkler <br /> Pressure Tem�.Ratin Ambierrt Tem . Length <br /> Size Inch(mm) si(bar) °F °C °F aC K Factor �nch(mm) <br /> Yz"NPT Yz"(13) 175(12) 155 68 100 38 5.8(83.5) 2.25(57) <br /> (R'/z) 175 79 150 66 <br /> Ordinary Temp.Rating Intem�ediate Temp.Rating Top of Deflector Minimum <br /> Max.Coverage ar� Max.Spacing 155°Fi68°C 175°F/79°C to Ceiling Spacing <br /> Ft x Ft(m x m) Ft(m) Flow Pressure Flow Pressure <br /> Inch(mm) Ft(m) <br /> GPM in PSI b� GPM Lhnin PSI bar <br /> 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6(0,53) 16(61) 7.6(0,53) Smooth Ceilings 1Ya to 4(31.7 to <br /> 102)using F2 escutcheon. <br /> 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6(0,53) 16(61) 7.6(0,53) 1 to 4(25.4 to 102)using F1 <br /> escutcheon. <br /> 16 x 16(4,9 x 4,9) 16(4,9) 16(61) 7.6(0,53) 16(61) 7.6(0,53) Beamed Ceilings per NFPA 13D, 8(2,4) <br /> 13R or 13 installed in beams <br /> 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 10.8(0,75) 19(72) 10.8(0,75) 1'/a to 13/a (31.7 to 44.4)using <br /> F2 escutcheon,1 to 13/a(25.4 to <br /> 20 x 20(6,1 x 6,1) 20(6,1) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 44.4)using F1 escutcheon <br /> For Ceiling rypes refer to NFPA 13, 13R or 13D <br /> 3. <br />