To: Diane Eiden Page 6 of 8 2005-11-08 15:37:22(GMT) 16126773930 From: Kendra FJersted <br /> � Make and Model Nutnber <br /> I <br /> � Air Leekage: <br /> [ ] � Joints,penetrations,and all other such openirigs in the building envelope that are sources of air <br /> � leakage must be sealed. <br /> [ ] I Recessed lights must be 1)Type IC rate8,or 2)installed inside an appropriate air-tight assembly <br /> � with a 0.5"clea:ance from combustible materials.If non-IC rated,the fixture must be installed with a <br /> � 3"clearance from insulation. <br /> � <br /> � Skyll�hts: <br /> [ ] � Minimum insulation requirement for skylight shafts equal to or greater than 12 inches ia R-19. <br /> I <br /> � Vspor Retardew <br /> ( ] � Required on the warm-in-winter side of ail non-vented framed ceilings,walls,and floora. <br /> I <br /> � Materials Identificadon: <br /> [ J � Materials and equipment must be installed in accordance with the manufacturer's installation instructions. <br /> [ ] � Materials and equipment must be identi5ed so that compliance can be determined. <br /> [ ] � Manufacturer manuals for all installed heating and cooling cquipment and service water heating <br /> � equipment must be provided. <br /> [ J � Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on <br /> � the buildir►g plans or specifications. <br /> � <br /> � Duct Insuladon: <br /> [ ] � Supply ducts in unconditioned attics or outside the building must be insulated to R-11. <br /> [ j � Return ducts in unconditioned attics or outside the buiiding must be insulated to R-6. <br /> [ J � Supply ducts in unconditioned spaces must be ir�sulated to R-11. <br /> [ J � Return ducts in unconditioned spaces(except basements)must be insulated to R-2. <br /> [ ] � Where exterior walls are used as plenums,the wall must be insulated to R-11. <br /> � Inaulation is not require8 on return ducts in basements. <br /> � <br /> � Duct Construction: <br /> [ ] � Duct connections to flanges of sir distribution system equipment must be sealed and mechanically fastened. <br /> [ ] � A11 joints,seams,and connectioru must be securely fastened with welds,gaskets,mastics(adhesives), <br /> � mastic-plus-embedded-fabric,or tapes. Tapes and mastics must be rated UL 181 A or UL 181 B. <br /> � Bxcaptlon:Continuously welded and locking-type longitudinal joints and seams on ducts <br /> � operating at less than 2 in.w.g.(500 Pa). <br /> [ ] � The HVAC system muat provide a means for balancing air and water systems. <br /> � <br /> � Temperatw-e Contr�ols: <br /> [ J � Thermostats are required for each separate HVAC system. A manual or automatic means to <br /> � partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. <br /> I <br /> � Se�vice Water Headn�: <br /> [ ) � Water heaters with vertical pipe risers must have a heat trap on both the irilet and outlet unless the <br /> � water heater has an integral heat trap or is part of a circulating system. <br /> [ ] � Irrsulate circulating hot water pipes to the levels in Table 1. <br /> � <br /> � Circuladn�Hot Water Systems: <br /> [ ] � Insulate circulating hot water pipes to the levels in Table 1. <br /> � <br /> � S�vimmin�Poola: <br />