Laserfiche WebLink
' C�1 F O R T E � MEMBER REPORT LowerLevel, WdwhdrFamilyRoom PASSED <br /> 2 piece(s) 13/4" x 11 7/8" 1.55E TimberStrandp LSL <br /> Overall Leng�:8'9' <br /> + + <br /> 0 0 <br /> � : , 9� �� <br /> 0 Q <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> F�i�t�, �'�LoCatlon A�MDrred:�, `;' ` i�F- 31MI��p: System:Wall <br /> Member Reaction(Ibs) 10887 @ 3" 11419(4.50") Passed(95%) -- 1.0 D+OJ5 L+0.75 S(All Spans) Member rype:Header <br /> Shear(Ibs) 5689 @ 1'4 3/8" 8590 Passed(66%) 1.00 1.0 D+1.0 L(All Spans) sui�dinq use:r�denhai <br /> Moment(Ft-Ibs) 15652 @ 4'S 7/16" 15953 Passed(98%) 1.00 1.0 D+1.0 L(All Spans) suilding code:IBC <br /> Live Load Defl.(in) 0.260 @ 4'9 7/16" 0.308 Passed(U427) -- 1.0 D+1.0 L(All Spans) oesign Methodology:ASD <br /> Total Load DeFl.(in) 0376 @ 4'9 1/2" 0.463 Passed(UZ95) -- 1.0 D+1.0 L(All Spans) <br /> •Defledbn viteria:LL(L/360)and TL(L/240). <br /> •Bracing(Lu):All compression edges(top and bottom)must be braced at 1'2 9/16"o/c unless detailed otherwise.Proper attachmeM and positionirg of lateral <br /> bracing is required to achieve member stability. <br /> BYaliny �.A1di rb'¢!�p�q�s j�j � �'-.. <br /> �P��"� 3ofal,. "� ite9ubaA '�� , ',� . ; '���;'.�odac '. <br /> 1-THmmer-SPF 4.50" 4.50" 4.29" 4285 5916 2866 13087 None <br /> 2-Trimmer-SPF 4.50" 4.50" 3.59" 3678 4474 2771 10923 None <br /> Trlbuary Oe�d Huo�'ilve SDOw <br /> Wads'' �ocarton ' wwth {0.90) (3:�3 ' (�ti� C�nr� <br /> 1-Uniform(PSF) 0 to 3'8" 15' 15.0 40.0 - Mafn level floor bad <br /> 2-Uniform(PLF) 0 to 9'9" N/A 9p,0 _ _ Main level exterior <br /> wall load <br /> 3-Unrfortn(PSF) 0 to 9'9" 6' 10.0 40.0 - Detk load <br /> 4-Uniform(PSF) 0 to 9'9" 15' 15.0 40.0 - Main level floor load <br /> Linked from:Wdw <br /> 5-Point(Ib) 0 N/A 1711 - 2886 hdr Great Room, <br /> su rt 1 <br /> Linked from:Wdw <br /> 6-Point(Ib) 9'9" N/A 1645 - 2771 hdr Great ROom, <br /> Su 2 <br /> 1NeyEr�faeuSer Nob85 ` , ' " �SUSTAINABLE FORESTRY INRIAi1VE <br /> Weyerhaeuser warrards that the sizing of its products will be in accordance with Weyerhaeuser product design crtteria and published design values. <br /> Weyerhaeuser e�cpressly disclaims any otfier warrandes related to the software.Refer to curceM Weyerhaeuser litereture far installation details. <br /> (www.woodbywy.com)Actessories(Rim Board,Blocking VanHs and Squash Blaks)are no[designed by this software.Use of this software is rwt irnended to <br /> drcumveM the need for a design professbnal as determined by the auttwrity having jurisdiction.The designer of record,buAder or framer is responsible to <br /> aswre that thfs calculatlon is mmpatiWe with the overall project.Products manufactured at Weyerhaeuser facilides are third-party certified to sustainable <br /> forestry stanAards. <br /> The product appBcatlon,input design loads,dimensions and wpport informatlon have been provided by Plan date:06/OS/2015 <br /> Forte Software Operator Job Notes 8/6/2015 9:12:33 AM <br /> John Nelsen Advance Homes Forte v4.6,Design Engine:V6.1.1.5 <br /> Lyman Lumber 2560 Kelly Ave 2560 Kelly Ave Excelsior MN.4te <br /> (952)470-4803 Excelsior MN <br /> i john_nelsen@IymaNumbeccom #20529 08/05/2015 PBge 33 Of 43 � <br /> L---- --_.--- -------- —----.._--------- ......----- � <br />