�F 0 R T E �L MEMBER REPORT Main Level,DrhdrFoyer PASSED � <br /> 2 piece(s) 1 3/4"x 9 1/2" 1.55E TimberStrand0 LSL <br /> Overall Length:6'6" <br /> + + <br /> 0 0 <br /> � s, � <br /> 0 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;D2wing is Conceptual <br /> q�SSU�S. ,:, �9lotillop " > .,AUQrr�d� , "� ' 1�fF., Lb1�:CawbiAalqoh{pi�) , System:Wall <br /> Member Reaction(Ibs) 2804 @ 1 1/2" 7613(3.00") Passed(37%) -- 1.0 D+1.0 S(All Spans) rtember Type:Header <br /> Shear(Ibs) 1906 @ 1'1/2" 7902 Passed(24"/0) 1.15 1.0 D+1.0 S(All Spans) Building Use:Residentlal <br /> Moment(Ft-Ibs) 4213 @ 3'3" 11985 Passed(35%) 1.15 1.0 D+1.0 5(All Spans) suiiding code:ieC <br /> Live Load DeFl.(in) 0.060 @ 3'3" 0.208 Passed(U999+) -- 1.0 D+1.0 S(All Spans) Design Mettaddogy:ASD <br /> Total Load DeFl.(in) 0.095 @ 3'3" 0.313 Passed(U�87) -- 1.0 D+1.0 S(All Spans) <br /> •Defiectan criteria:LL(l/360)and TL(U240)• <br /> • Bracing(Lu):All compresslon edges(top and bottom)must be braced at 6'6"o/c unless detailed otherwise.Proper attachment and positioning of lateral <br /> bracing is requfred to achfeve member stability. <br /> ��arMp. ��D���) <br /> � > ' ' TOAai A+ia�ble`; �tiqoMeA • Dbwd; '.Swow'� tolaf 11aa6n�xlas <br /> 1-Trimmer-SPF 3.00" 3.00" 1.50" 1041 1763 2804 None <br /> 2-Trimmer-SPF 3.00" 3.00" 1.50" 1041 1763 2804 None <br /> 7Yi�uGtY Yead S�o�` <br /> I.�d6< ia�on INWtI� '(p,tq) {1-1�' Cop�meMs <br /> 1-Uniform(PSF) 0 to 6'6" 15'6" 20.0 35.0 Snow-main <br /> WeyCifieeuser NOtes f�SUSTAINABLE f-0RESTRY INRIATIVE <br /> Weyerhaeuser warrarrts that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. <br /> (www.woodbywy.com)Accessories(Rim Board,Bbcking Pan�s and Squash Blockt)are not designed by this soRware.Use of this software is not intended to <br /> circumveM the need fa a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this plculation is compatible with the ove211 project.Productr manufactured at Weyerhaeuser facNitks are third-party certified to sustainable <br /> forestry standards. <br /> The produd ap�ication,input design loads,dimensions and support infortnadon have been proWded by Plan date:06/OS/2015 <br /> Forte sot�ware oPerasor Job Notes 8!6/2015 9:12:30 AM <br /> John Nelsen Advance Homes Forte v4.6,Design Engine:V6.1.1.5 <br /> Lyman Lumber 2560 Kelly Ave 2560 Kelly Ave Excelsior MN.4te <br /> (952)470-4803 Excelsior MN <br /> john_nelsen@lymanlumber.com � #205290R/05;20?5 � � � P8g@ 22 Of 43 <br />