Laserfiche WebLink
� . �F 0 R T E ro MEMBER REPORT Main Level, Wdw hdr NW Bedroom-rear(2) PASSED <br /> 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 <br /> Overall Lenglh:2'3' <br /> + + <br /> 0 0 <br /> � <br /> � Z. � <br /> � 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> R��i � . Jl�ual�lO�tiOn . AY�rad .:, �t iDF-.�,lo�A•-f:o�il�l�l�oa:�'�iNn1 . "-: . ' System:Wall <br /> Member Reaction(Ibs) 348 @ 0 1913(1.50") Passed(18%) -- 1.0 D+1.0 S(All Spans) Member Type:Header <br /> Shear(Ibs) 71 @ 10 3/4" 2872 Passed(2%) 1.15 1.0 D+1.0 5(All Spans) Building Use:Residendal <br /> Moment(Ft-Ibs) 196 @ 1'1 1/2" 3946 Passed(5%) 1.15 1.0 D+1.0 S(All Spans) Building Code:IBC <br /> Live Load Defl.(in) 0.000 @ 1'1 1/2" 0.075 Passed(U999+) -- 1.0 D+1.0 S(All Spans) Design Merhodology:nso <br /> ToWI Load Defl.(in) 0.001 @ 1'1 1/2" 0.112 Passed(U999+) -- 1.0 D+1.0 S(All Spans) <br /> • Defled'an criterfa:LL(L/360)and 1'L(L/240). <br /> • Bracing(Lu):All compression edges(top and bottom)must be braced at 2'3"o/c unless detailed othenvise.Proper attachment and positionirg of late2l <br /> b2cing is required to achieve member stabiliry. <br /> •Applicable cakulations are based on NDS 2005 methodology. <br /> Hear�Y �!b0�pfo��#�t)q <br /> $U p0175 4otel-r-Availabla ' �d .':b�rii' :�noiM'> „`�ptAl �1Cpa�io�i�p;: <br /> 1-Trimmer-SPF 1.50" 1.50" 1.50" 132 217 349 None <br /> 2-Trimmer-SPF 1.50" 1.50" 1.50" 132 217 349 None <br /> Tribub�rY Daad Snow ` <br /> 1.08t1S� �� Locatioe WWth �. (0.9U)� � s "j�,:i6) '� �m0���'- <br /> 1-Unifortn(PSF) 0 to 2'3" 5'6" 20.0 35.0 Snow-main <br /> W@yB1♦18eUSel'NO�S '���.. -- �. ` �� � ..� .. -. ,.,. , ..� �... .. ,�. (t�SUSTAINABLEFORESTRYINRIATNE <br /> Weyerhaeuser warrarrts fhat the sizing of its products will be in accordance wRh Weyerhaeuser product design criteria and published design values. 1 <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installadon d�ils. <br /> (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this soRware is not intended to <br /> circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this calculation is compatlble with the rnerall project.Products manufactured at Weyerhaeuser facitlties are third-party certified to sustainable <br /> forestry standards. <br /> The produd applicatlon,inqrt design loads,dimensions and support informatlon have been provided by PWn date:O6/OS/2015 <br /> Forte Software Operator �ob Notes 8/6/2015 9:12:28 AM <br /> John Nelsen Advance Homes Forte v4.6,Design Engine:V6.1.1.5 <br /> Lyman Lumber 2560 Kelly Ave 2560 Kelly Ave Excelsior MN.4te <br /> (952)470-4803 Excelsior MN <br /> john_nelsen@lymanlumber.com #20529 08/OS/2015 PaoP 11 nf 43 <br /> _ -- — ---- — ---.._---- _— -- --- � <br />